Figure 5-6 Data Capture Example - Siemens SITRANS F FS200 Utility Programming Manual

Ultrasonic flowmeters
Table of Contents

Advertisement

Diagnostic Screens
Siemens Data Capture Log
FS200 Utility Version
Long Tag
Product S/N
COMS Settings
Location Identifier
Meter Bore id
System Setup Parameters
------------------------------------------------------------------------------
Parameter
Pipe Diameter
Pipe Wall Thickness
Pipe Inside Diameter
Transducer Size
______________________________________________________________________________
Path Setup Parameters
Parameter
Mounting Mode
Sensor Spacing LTN
Sensor Frequency
Vsmin
Vsmax
______________________________________________________________________________
Column#
Label
1
Date
2
Time
3
Flow Rate(m3/h)
4
Status FR
7
VF1(m/s)
9
Avg VF(m/s)
10
VoS1(m/s)
12
Avg VoS(m/s)
13
Status 1
14
Status 2
15
RX Gain(up) 1
17
RX Gain(dn) 1
19
DT 1(uS)
21
SNR(up) 1
23
SNR(dn) 1
25
CorQ 1
27
%ACP 1
29
Temp(F)
30
Press(PSIA)
31
Density(lbm/ft3)
32
Viscosity(cS)
Date
Time
Flow Rate(m3/h)
3/16/2020
13:19:22
3/16/2020
13:19:25
3/16/2020
13:19:28
3/16/2020
13:19:31
3/16/2020
13:19:34
3/16/2020
13:19:37
3/16/2020
13:19:40
3/16/2020
13:19:43
3/16/2020
13:19:46
3/16/2020
13:19:49
3/16/2020
13:19:52
Average Value
Minimum
Maximum
Warning Limit
Simulation Mode
Failure Limit
Pass
# ofWarnings
# of Failures
# of Samples
11
Figure 5-6 Capture Log Example
Special Notes for the Data Capture file:
1. The FS200 utility capture file will only contain fields pertinent to the installation. For
20
1.00.02
N1J4118000027
Baud:19200
Value
D4H
Path 1
Direct
Description
Query Date
Query Time
Meter Flow Rate(m3/h)
Status Flow Rate
Flow Velocity path 1(m/s)
Avg. Flow Velocity(m/s)
VoS path 1(m/s)
Avg. VoS(m/s)
Status path 1
Status path 2
Upstream Xmit RX Gain(up) path 1
Downstream Xmit RX Gain(dn) path 1
Transit-time Delta path 1(uS)
Upstream Xmit SNR(up) path 1
Downstream Xmit SNR(dn) path 1
Correlation Factor path 1
Accepted Burst Percentage path 1
Temperature(F)
Pressure(PSIA)
Density(lbm/ft3)
Viscosity(cS)
Status FR
136.1288 Pass
136.0898 Pass
136.1612 Pass
136.0763 Pass
135.934 Pass
136.0927 Pass
136.0052 Pass
135.755 Pass
135.6573 Pass
136.0195 Pass
136.1911 Pass
136.0101
136.1911
135.6573
Simulation Mode
Pass
0
0
0
0
example, a Dual Path system with only Path-1 enabled will not present any data columns
Parity:None
3.937 inches
Units
4.537 inches
0.3 inches
3.937 inches
Path 2
Direct
0.4204
187500
197.2924
402.7076
Standard
Volume Flow
Rate(Nm3/h)
Status SVFR
1928.6162 Pass
1927.9778 Pass
1928.4122 Pass
1927.1472 Pass
1924.6659 Pass
1927.6021 Pass
1925.5692 Pass
1922.4499 Pass
1920.7065 Pass
1927.0039 Pass
1928.8372 Pass
1926.2717
1928.8372
1920.7065
Simulation Mode Simulation Mode > 2%
Pass
Pass
0
0
Data Bits:8
Units
0.4204 inches
187500 Hz
197.2924 mps
402.7076 mps
VF1(m/s)
VF2(m/s)
5.096
4.953 361.49
5.126
4.934 361.33
5.112
4.948 361.48
5.096
4.955 361.52
5.08
4.976 361.59
5.045
4.999 361.49
5.03
5.014 361.5
5.029
4.996 361.45
5.058
4.971 361.55
5.06
4.984 361.63
5.07
4.984 361.61
5.073
4.974 361.51
5.126
5.014 361.33
5.029
4.934 361.63
> 2%
Measurement
Measurement > 0.50% Or not Measurement
0
0
0
0
0
0
FS200 Programming Manual, 03/2020,