No.
Items
P148
The back time of thread
tension releasing in the
mode of clamp function
without any thrum
P151
Hook thread function
P152
The delay time of hook
thread
P153
The continuous time of
hook thread
P154
The back time of hook
thread
P155
Hooking thread
operation duty cycle
(%)
P156
Presser foot lifter
operation duty cycle
(%)
P157
The initial output angle
of presser foot while
starting tack
P158
The end output angle of
presser foot while
starting tack
P159
Suction function
P160
Suction time (ms)
Note: the initial value of parameters is for reference only, and the actual value of parameters is subject to the real object.

3 Error Code List

Error Code
Problem description
E01
Over-voltage
E02
Low-voltage
E03
CPU communication error
Range
Default
0-990
30
0-1
1
0-990
10
0-990
150
0-990
30
0-100
90
0-100
0
1-359
1
1-359
300
0-1
1
5-5000
500
Turn off the machine, check the power supply voltage. (Or whether exceed
the rated voltage of use).
If there are still errors, please replace the control box and call for customer
service.
Turn off the machine, check the power supply voltage. (Or whether under
the rated voltage of use).
If there are still errors, please replace the control box and call for customer
service.
Turn off the machine, please check if the operation panel in bad connection
or is too loose. To get it right and turn on. If there are still errors, please
replace the control box and call for customer service.
18
Description
Back time
0:OFF 1:ON
Delay time
Continuous time
Back time
Hook thread in duty cycle to save electricity and protect the
electromagnet from over-heat
Presser foot lifter operation in duty cycle to save electricity and
protect the electromagnet from over-heat
Initial output angle
End output angle
0:OFF 1:ON