Download Print this page

Auxiliary Function; User Parameter - Siruba DL7200B Manual

Electronic control parameter
Hide thumbs Also See for DL7200B:

Advertisement

Automatic
Presser Foot
Lifting
Setting
Clamp
Function
Setting
Thread
Trimming
Slow Launch
Setting
Needle Stop
Position
Selection
Fill Up
Needle

1.2 Auxiliary function

1.2.1 Restore Factory Setting
On the main interface long-press one-shot sewing key, restore factory setting.
1.2.2 Needle Stop Position Function Setting
In the main interface, click the P key to enter the parameters, and set the parameters to P72. Manually rotate
the handwheel to up position. The value displayed will change with the change of the wheel position. Press S key
to save the current position (value) as the upper pin stop and calculate down position automatically.
1.2.3 Lock Screen Function
In the main interface, when no operation time reaches the time (s) set by item p27-n01, the lock screen will be
automatically locked, or long-press "S" key to lock screen. In the lock screen "LOCK" state, click the "S" key to
unlock.

2 User Parameter

No.
Items
Maximum sewing
P01
speed(rpm)
Set accelerated curve
P02
(%)
P03
Needle UP/ DOWN
Start back-tacking
P04
speed(rpm)
End back-tacking speed
P05
(rpm )
Bar-tacking speed
P06
(rpm)
P07
Soft start speed(rpm )
1. Automatic presser foot lifting after trimming function when
2. Automatic presser foot lifting after pause function when
3. Automatic presser foot lifting after pause function or trimming function when
icon and
icon are lighting.
4. Presser Foot is inactive when
Set used or cancelled clamp function.
If click, set used or cancelled thread trimming function.
If click, set used or cancelled slow launch function.
If click, the needle stop position after shift the sewing mode ( Up position / Down
position)
If click, set used or cancel fill up needle function.
Range
Default
100-3700
3700
10-100
80
UP/DN
DN
200-3200
1800
200-3200
1800
200-3200
2000
200-1500
400
icon and
Maximum speed of machine sewing
Set the acceleration slope
UP: Needle Stops at Up Position
DN: Needle Stops at Down Position
Set Start Back-Tacking Speed
Set End Back-Tacking Speed
Set Repeat Bar-Tacking Speed
Set Soft Start Speed
12