Download Print this page

Siruba DL7200B Manual page 15

Electronic control parameter
Hide thumbs Also See for DL7200B:

Advertisement

No.
Items
End back-tacking
P25
compensation 3
End back-tacking
P26
compensation 4
P27-N01
Lock screen clock
Backlight
P27-N10
brightness settings
Backlight
P27-N11
extinguishing
time setting
Start machine display
P27-N12
counter interface
selection
P27-N13
Counter mode selection
Bar-Tacking running
P28
mode selection
Bar-Tacking
P32
compensation 5
Bar-Tacking
P33
compensation 6
Constant-Stitch Sewing
P34
running mode selection
Thread slacking
P36
function selection
Automatic thread
wiping function /
P37
Automatic thread
clamping function
selection
Automatic thread
P38
trimming function
selection
Automatic presser foot
P39
lifting when pause
function selection
Automatic presser foot
P40
lifting after trimming
function selection
P41
Counter display
P42
Information Display
Direction of Motor
P43
Rotation
Range
Default
0-200
131
0-200
158
0-300
0
0-3
2
0-200
30
0-1
0
0-1
0
0-3
1
0-200
131
0-200
158
A/M
A
0-11
5
0-11
1
ON/OFF
ON
UP/DN
DN
UP/DN
DN
0-9999
CCW/CW
CCW
14
Description
Stitch Balance for end back-tacking C section, 0~200 action
gradually delay; the large value, the shorter of the C section first
stitch.
Stitch Balance for end back-tacking D section, 0~200 action
gradually delay; the large value, the longer of the C section last
stitch, and the shorter of the D section first stitch.
When the parameter value is 0, the lock screen function is
invalid.
When the parameter value is 0, the backlight brightness remains
the same.
0: OFF
1: ON
0: Addend sewing counter 1: Subtrahend sewing counter
0: Could be arbitrarily stop and start
1: Automatically perform actions
Stitch Balance for start back-tacking A (C) section, 0~200 action
gradually delay; the large value, the longer of the A (C) section
last stitch; the shorter of the B(D) section first stitch.
Stitch Balance for start back-tacking B (D) section, 0~200
action gradually delay; the large value, the longer of the B (D)
section last stitch; the shorter of the C section first stitch.
A:Automatically perform actions
M:Could be arbitrarily stop and start
0: OFF
1-11: The strength of thread slacking
0 : OFF
1: Automatic thread wiping Function
2-11: Automatic thread clamping Function and the strength of
automatic thread clamping.
ON: ON
OFF: OFFF
UP: ON
DN: OFF
UP: ON
DN: OFF
Display the quantity of finished sewing piece.
N01 The control system version number
N02 The panel version number
N03 Speed
N04 The pedal AD
N05 The mechanical angle(up position)
N06 The mechanical angle(down position)
N07 Busbar voltage AD
N12 Kneeling device position sensor AD
CW: Clockwise
CCW: Counter Clockwise