Download Print this page

Siruba DL7200B Manual page 18

Electronic control parameter
Hide thumbs Also See for DL7200B:

Advertisement

No.
Items
The oil level alarm
P120
switch selection
Thread trimming mode
P121
selection
Prevent taking off the
thread after thread
trimming mode, timing
P122
of back-tacking
operation before thread
trimming
Small thread end mode,
timing of back-tacking
P123
operation when thread
trimming
P124
Press Foot of knee
lifting release buffer
duty cycle
P139
The function of thread
tension releasing while
starting tack
P140
Thread tension
releasing mode
P141
The start angle of
thread tension releasing
while starting tack
P142
The end angle of thread
tension releasing while
starting tack
P146
The delay time of
thread tension releasing
in the mode of clamp
function without any
thrum
P147
The continuous time of
thread tension releasing
in the mode of clamp
function without any
thrum
Range
Default
0-1
0
0-3
0
0-1439
1000
0-100
25
0-50
10
0-1
0
0-2
0
1-359
1
1-359
270
0-990
150
0-990
120
17
Description
0: OFF 1: ON
0: Normal mode
1: Small thread end mode
2: Prevent taking off the thread after thread trimming mode
3: Small thread end mode and prevent taking off the thread after
thread trimming mode
The greater the value, the greater the one stitch before thread
trimming.
0:OFF 1:ON
0:Thread trimming
1:Start tack
2:clamp function without any thrum
Start angle
End angle
Delay time
Continuous time