Download Print this page

Siruba DL7200B Manual page 17

Electronic control parameter
Hide thumbs Also See for DL7200B:

Advertisement

No.
Items
Presser foot release
P71
operation duty cycle
(%)
Up needle position
P72
adjustment
Down needle position
P73
adjustment
Back-tacking operation
P76
time to full output ( ms)
The start angle of
P78
thread clamping
The stop angle of
P79
thread clamping
The start angle of
P80
thread trimming
The stop angle of
P82
thread trimming
Wiping thread return
P87
delay time
Correct the electrical
P92
angle of motor
The delay time of the
P93
half back pedaling
function
End Back-Tacking
P99
compensation C1
End Back-Tacking
P100
compensation D1
The start angle of
P101
thread slacking
The stop angle of
P102
thread slacking
Trimming back time
P110
(ms)
The delay time of the
P117
presser foot release
damping force (ms)
Electromagnet
P119
overcurrent protection
selection
Range
Default
0-50
5
0-1439
0-1439
10-990
250
5-359
100
5-359
270
5-359
18
5-359
175
10-990
50
160
10-900
200
0-250
120
0-250
175
1-359
30
1-359
180
60-990
200
0-990
12
0-1
0
16
Description
The buffer force of presser foot release operation.
Hand rotation manual to the appropriate position, press S key to
save.
Hand rotation manual to the appropriate position, press S key to
save.
Back tacking start action, full output action times.
Shear line infeed id angle setting(under defined as 0°)
Feeder back angle of thread trimming setting Down position as
0°, the value need greater than the P80 parameter item)
Make sure the wiper returns to its original position
Review the user manual 1.5
Reading the initial Angle of encoder, the factory default was set,
please do not change the values (parameter value cannot be
changed manually, random change it will result the control box
and motor abnormal or damaged).
Prevent taking off the thread after thread trimming mode,
compensation for C part of End Back-Tacking.
Prevent taking off the thread after thread trimming mode,
compensation for D part of End Back-Tacking.
Song line start angle (defined as 0°under calculation)
Loose wire end angle (defined as 0°under calculation)
Make sure the trimming device returns to its original position
0: OFF 1: ON

Advertisement

loading