Stabilizer Guide Track Bracket
Make sure to keep a minimum 5 mm (
the bed lift. Install the stabilizer guide track brackets (Fig. 12D) as close as possible to the side of the bed
(Fig. 12C) to avoid a tip-over when under load.
NOTE: The stabilizer guide track bracket (Fig. 16A) locations may vary per bed.
1.
Place the stabilizer guide track bracket (Fig. 16A) on the end rail frame, as close as possible to the side
of the bed frame.
2.
Use a 4.0 mm (5/32 in) drill bit to pre-drill the side hole (Fig. 16B).
3.
Install a 4.2 mm x 13mm screw (Fig. 16C) in the side hole of the stabilizer guide track bracket.
4.
Use a 4.0 mm (5/32 in) drill bit to pre-drill the top of the end rail hole (Fig. 16D).
5.
Install a 4.2 mm x 13 mm screw (Fig. 16E, Fig. 17B) with a #5 washer (Fig. 16F) into the belt bracket top
hole (Fig. 16D) and into the end rail (Fig. 17B).
6.
Repeat steps 1-5 for the other stabilizer guide track bracket.
E
A
D

Belt Mounting Brackets

1.
Remove the tape holding the belts in the rolled-up position on the drive shaft.
2.
Feed the short belts into the closest end rail belt brackets (Fig. 18A) and feed the long belts into the
opposite end rail belt brackets (Fig. 19A).