Moving The Platform Machines With Electric Controls - Snorkel MHP 15/44HD Operator's Manual

Hide thumbs Also See for MHP 15/44HD:
Table of Contents

Advertisement

To start the en gine from the plat form con trol box
you must first set some switches on the ground
con trol box, in clud ing set ting the sta bi lis ers and
lev el ling the ma chine.
(See page 9-2 for in for ma tion on set ting the sta bi -
lis ers)
1. Insert the key
into the Master Key Switch
at the ground control box and turn the key on
(see Figure 10.11).
Figure 10.11
2. Set the Platform/Ground Selector
Figure 10.11) at the ground control box to
PLATFORM.
3. Set the Booms/Stabiliser Selector to
BOOMS
Figure 10.12
4. Enter the platform, close the gravity gate
and attach the lanyard of your fall restraint
(safety harness) to one of the anchor points
(see Figure 10.12).
MHP15/44HD – 12885A
5. Set the Emergency Stop switch
(see Figure 10.13).
6. Turn the Anti-Restart switch
Figure 10.13).
7. If the engine is at ambient temperature (cold),
hold the Choke Switch
up throughout the next step.
8. Turn the Anti-Restart switch
and hold it there until the engine starts or for
a maximum time of 6 seconds. When the
engine starts, release the key (6) and the
choke switch
10.13).
If the engine does not start in 6 seconds, turn
the Anti-Restart switch OFF.and release the
choke. Wait 60 seconds before trying to
restart the engine again. Continual cranking
(see
of the starter motor will only result in its
damage.
The en gine should now be run ning, and the
MHP15/44HD is ready to be gin work.
Moving The Platform
Machines with Electric Controls
The engine should already be running (as
described earlier in this chapter), before you start
this section.
DO NOT operate near energized electrical
conductors. Maintain the (M.S.A.D.),
Minimum Safe Approach Distance to
energized power lines. See the "Electrical
Hazard" section, in this manual for a
,
complete explanation of the hazards
c o n c e r n i n g e l e c t ri c i t y . M a i n ta i n t h e
clearances shown on the decal attached to
the platform.
Rev F
10. Operation
Figure 10.13
to (ON)
to ON (see
(see Figure 10.13)
to START
, if you used it (see Figure
CAUTION
DANGER
page 10 - 5

Advertisement

Table of Contents
loading