Operating Instructions; Operating Sequence - Maytag PHASE 7.2 User Manual

Table of Contents

Advertisement

The Phase 7 OPL microprocessor controller (computer) allows the operator to choose from six (6) preprogrammed
cycles (keys "A-F"). These have been preprogrammed by the factory with the parameters (programs) shown
in Section VII. There are an additional ("0-40") preprogrammable cycles that are preprogrammed by the
factory with the parameters (programs) shown in Section VII. For occasional or onetime special loads, the
Manually Loaded Cycles can be used where the operator must set the specific program(s) needed.
NOTE: Refer to Section III of this manual for a complete explanation of the various cycles/selections
available.
After the load is put into the basket (tumbler) and the dryer is ready to dry, determine which cycle will best suit
the application (type of load). We recommend using the Automatic Drying Cycle (Patent No. 4,827,627) for
most loads. This cycle provides for the best drying in the shortest time, ALL automatically.
A. OPERATING SEQUENCE
1. Preprogrammed Cycles
a. Automatic Drying Cycle (Patent No. 4,827,627)
1) Light emitting diode (L.E.D.) display reads "READY" (no cycle in progress).
2) Press the letter on the keyboard (touch pad) corresponding to the cycle desired (i.e., key "A").
NOTE: "0-40" will require the "START/ENTER" key to be pressed after the number is selected in
order to accept the selection and start drying.
3) The dryer will then start. (I.E., Blower, basket [tumbler], and heat).
4) L.E.D. display reads AUTO DRYING CYCLE "A," ELAPSED TIME __ MIN 00:00. During the
drying cycle, the Phase 7 OPL microprocessor controller (computer) will monitor the amount of
moisture in the load. Once the temperature is above 160º F (71º C), the Cycle Status portion of the
L.E.D. will change from ELAPSED TIME __ MIN to __ % DRY. The display will count upward
until the percentage of extraction programmed is reached.
NOTE: Press and hold the "UP ARROW" to view the basket (tumbler) temperature at any time.
NOTE: The dryer can be stopped at any time by pressing the "STOP/CLEAR"
dryer will go into a cycle pause. If the "STOP/CLEAR"
the cycle that was in progress will be cancelled and returned to the "READY" state.
SECTION IV

OPERATING INSTRUCTIONS

13
key, at this time the
O
key is pressed again at this point,
O

Advertisement

Table of Contents
loading

Table of Contents