3. ENTER AUDIO ALERT ON TIMES 0 TO 10 - This selection allows the operator to adjust the
amount of signal tones. This parameter (program) affects the tone at the end of the Cool Down
Cycle, as well as, at the end of the Wrinkle Guard On Time.
4. ROTATIONAL SENSOR (Optional) - This selection is used to turn the optional rotational sensor
on or off.
1. REVERSING SETUP - The parameters that pertain to the reversing mode are in this menu level.
0. ENTER SPIN TIME 30 TO 120-SECONDS - This parameter (program) is fixed at 2 minutes in the
forward direction and 2 minutes in the reverse direction for the Automatic Mode. In the Manual Mode,
it is programmable. This Spin Time is programmed here for the Manually Loaded Manual Cycle only.
1. ENTER STOP TIME 5 TO 10-SECONDS - This parameter (program) is fixed at 5-seconds in the
Automatic Mode and programmable in the Manual Mode. This Dwell (stop) Time is programmed here
for the Manually Loaded Manual Cycle only.
2. WRINKLE GUARD SETUP - The parameters that pertain to the Wrinkle Guard is in this menu level.
0. WRINKLE GUARD AUDIO ALERT - This parameter (program) allows the operator to turn the
Audio Alert tone on or off at the end of each Wrinkle Guard Cycle. The amount is the same that is
selected in "DRYER SETUP" for AUDIO ALERT ON TIMES 0 TO 10.
3. STEAM INJECTION (Optional) - This parameter is used to inject steam into the basket (tumbler) up
to 5 times into the basket (tumbler). 0-5 on time is first entered MM:SS (minutes:seconds) and then the
off time is entered MM:SS (minutes: seconds).
2. PROGRAM "A-F" CYCLE - This menu allows the programming of cycle "A-F." The parameters selected
in this menu for each letter will be stored in memory for that key. This will allow the operator to utilize one
(1) touch drying through keys "A-F."
3. PROGRAM "0-40" CYCLE - This menu allows the programming of cycle "0-40." The parameters
selected in this menu for each number will be stored in memory for that number key(s). This will allow the
operator to utilize preprogrammed drying cycles stored in memory under a numerical location.
NOTE: BOTH THE "A-F" and "0-40" ALLOWS FOR A TOTAL OF 47 PREPROGRAMMED
LOCATIONS FOR CUSTOM DRYING.
4. DEFAULT SETTINGS - This menu allows the operator to set ALL the programmable parameters to the
default settings. This option has a password selection of 1 2 3. It will then ask to confirm settings. It will
default to "NO." Use the arrow keys to select "YES."
CAUTION: Once the settings have been set to their default settings, there is no way to
retrieve the old settings. Use caution when using this feature .
5. SENSOR ACTIVATED FIRE EXTINGUISHING (S.A.F.E.) VALVE TEST - This is used to test the
S.A.F.E. system to verify valve is operating correctly. Press and hold start button to open valve.