If the parameter (program) change is a feature
change, such as changing the temperature
conversion from degree Fahrenheit (ºF) to
degree Celsius (ºC) or from "AUTO"
(Automatic Drying Cycle - [Patent No.
4,827,627]) to "MANUAL" (Timed [Manual]
Drying Cycle), the operator will press and hold
the "UP ARROW" or "DOWN ARROW" key.
This will toggle between choices. Once the entry
is made or if the parameter (program) does not
need to be changed, press the "START/
ENTER"
key and the Phase 7 OPL
l
microprocessor controller (computer) will
advance to the next program selection.
When making numerical changes, please keep
in mind to stay within the programming limits
shown. If an erroneous entry is made, the Phase
7 OPL microprocessor controller (computer) will
display "ERROR" and ignore the entry made
when the "START/ENTER"
and will return to the numerical value previously
set.
The Phase 7 OPL microprocessor controller
(computer) allows the operator to scroll through
the various parameters (programs) and select
the parameter to be changed. At this point, the
operator can go to the next Program Location
(system parameter) to be changed. If no other
programs (parameters) need to be changed, the
user can get out of the program mode by pressing
the "STOP/CLEAR"
O
programming mode. The Phase 7 OPL
microprocessor controller (computer) will be
returned to the operating mode, and the light
emitting diode (L.E.D.) display will read
"READY."
key is pressed
l
key until it is out of the
PHASE 7 OPL
PROGRAMMING LOCATIONS
TO ENTER PROGRAMMING MODE PRESS
TO EXIT PROGRAMMING MODE PRESS
UNTIL DISPLA Y RETURNS TO "READY."
0: SELECT LANGUAGE
1: SELECT SYSTEM PARAMETERS
0: DRYER SETUP
0: SELECT MODEL
1: SYSTEM TEMP
2: ENTER LINT COUNT 1 TO 5
3: ENTER AUDIO ALERT ON TIMES 0 TO 10
4: ROTATION SENSOR
1: REVERSING SETUP
0: ENTER SPIN TIME 30 TO 120 SECONDS
1: ENTER STOP TIME 5 TO 10 SECONDS
2: WRINKLE GUARD SETUP
0: WRINKLE GUARD AUDIO ALERT
3: STEAM INJECTION SETUP
2: PROGRAM A - F CYCLES
SELECT A - F KEY
SELECT CYCLE TYPE
AUTO
0: REVERSE MODE
1: ENTER DRY TEMP 160 (71) TO 200°F (94°C) *
2: ENTER DRYNESS LEVEL
3: ENTER CYCLE ADJUSTMENT VALUE 0 TO 99
4: CONTROLLED COOL DOWN
5: ENTER COOL DOWN TIME 0 TO 99 MINUTES
6: ENTER COOL DOWN TEMP 70 (21) TO 100°F (38°C)
MANUAL
0: REVERSE MODE
1: ENTER DRY TIME 0 TO 99 MINUTES
2: ENTER DRY TEMP 100 (38) TO 200°F (94°C) *
3: CONTROLLED COOL DOWN
4: ENTER COOL DOWN TIME 0 TO 99 MINUTES
5: ENTER COOL DOWN TEMP 70 (21) TO 100°F (38°C)
6: STEAM INJECTION
3: PROGRAM 0 - 40 CYCLES
ENTER 0 - 40
SELECT CYCLE TYPE
AUTO
0: REVERSE MODE
1: ENTER DRY TEMP 160 (71) TO 200°F (94°C) *
2: ENTER DRYNESS LEVEL
3: ENTER CYCLE ADJUSTMENT VALUE 0 TO 99
4: CONTROLLED COOL DOWN
5: ENTER COOL DOWN TIME 0 TO 99 MINUTES
6: ENTER COOL DOWN TEMP 70 (21) TO 100°F (38°C)
MANUAL
0: REVERSE MODE
1: ENTER DRY TIME 0 TO 99 MINUTES
2: ENTER DRY TEMP 100 (38) TO 200°F (94°C) *
3: CONTROLLED COOL DOWN
4: ENTER COOL DOWN TIME 0 TO 99 MINUTES
5: ENTER COOL DOWN TEMP 70 (21) TO 100°F (38°C)
6: STEAM INJECTION
4: DEFAULT SETTINGS
ENTER PASSWORD
(PRESS "1" "2" "3")
CONFIRM DEFAULTS
5: FIRE SUPPRESSION SYSTEM VALVE TEST
* 160°F (71°C) MAXIMUM TEMP ON AXIAL MODELS
21
p
AND
KEYS TOGETHER.
MULTIPLE TIMES
P/N:114521