Tank Fill Slowly - Environmental Water Systems EWS-IRON-1054-A Product And Installation Manual

Iron removal systems
Table of Contents

Advertisement

start up procedure - fill the tank and flush the system
fILL THe TANK - SLOwLY
13.
Main water supply is open, plumbing lines have
been flushed and tub or faucet is closed (Step #12)
Open the inlet slightly on the bypass
as shown
CAUTION:
Open slowly to prevent rapid flow and high initial pressure into the system
START UP TO fLUSH THe SYSTeM
14.
Press the Cycle button
in the lower right corner.
screen will change
Press the now button
Screen will read backwash in green box
This is a 14 minute cycle
which counts down by seconds
15.
After 1 minute, display in the top right box reads 13 minutes
OPeN THe INLeT ON THe BYPASS SLOwLY (inlet open position)
NOTe: this cycle allows air to be purged from system while filling the tank
little or no water will be seen coming out of the drain until tank
and iron filtration media is completely full of water.
NOTe: the remainder of the cycles will flush the system.
system is now flushing on its' own and you are almost done
now
backwash
13 m
59 s
open
inlet
slightly
water Treatment
wed
12:01 am
Regeneration
at regen time
water Treatment
wed
12:01 am
13 m
0 s
open inlet only
during system start up
13
outlet
closed
inlet
flow
1667
11 h
G
59 m
treatment
custom
now
13 m
59 s
backwash
custom
outlet
closed
inlet
open

Advertisement