location and setup
UNPACKING AND INSPeCTION - Check the system components for damage or missing parts.

wHeRe TO INSTALL THe SYSTeM

 Place system on the main water supply in order to supply filtered water to the entire home.
 Place the system where you want to install the unit. Whether inside or outside, make sure the unit is level and on a firm base.
 A standard grounded and unswitched 110/115/120v electrical outlet is needed to plug in the transformer. If outlet is over 9 feet away
use 18 gauge extension cord to connect up to 100 feet away. do not exceed 100 feet. do not cut or splice original equipment.
 do not install the system where it would block access to the water heater, or access to the main water shutoff, water meter, or
electrical panels. Always connect the system prior to the water heater(s).
 Install the system in a place where damage is least likely to occur if any unforeseeable issue arises. System should be in an
accessable location and be visable in order to visually monitor system and routinely check clock operation and valve controls.
CAUTION:
do not install on a soft water loop or bypass of other water lines where the filtered water will not be available for
household use. All Iron Systems are designed to filter all the water to the entire home.
CAUTION:
Installing other equipment in addition to this System? Softeners (if applicable) always go after the filtration system.
See Page 18 for proper order of installation. +Any questions? Please contact EWS for proper order of installation.
NOTE: Can be connected for outside faucets for plants, lawn, pools, spas, and other features. It is not necessary under normal circumstances
for any outside application. All Iron Systems will not harm these other features, however there will be more water usage through the system and
may not create any additional benefits for those features due to external environmental issues and porous or natural surfaces or materials.

DRAIN LOCATION

 Place the system as close as possible to a vented sewer drain with a "P" trap or some other drain location.
 Highly Recommended: Install a non-restrictive spring check valve in drain line within the first 2' of the drain port to prevent possible
back flow. (see below when a non-restrictive spring check valve is required)
REQUIRED:
Air gap with proper ventilation is a requirement. Similar to any washing machine, this sytem must have a
minumum of a 1" air gap on the drain to prevent back flow of drain water or gases into the system
REQUIRED:
Expand drain line to 1" Id and install a non-restrictive spring check valve in drain line within the first 2' of the drain
port if drain line exceeds 20' in total length, or drain line flows over 5' above the height of the drain port, or if
drain line is being routed outside.
CAUTION:
never install drain line smaller than 3/4" in diameter. never restrict drain line or drain water flow.
 Consider the reuse of drain water as an alternative to simply going down the drain.
Unlike salt or resin systems or softeners which have a brine discharge, all Whole home Water Filtration Systems drain only filtered
water in order to self-clean the filter. Water can go back to a pool for make up water or water a yard, trees and plants. you can use this
filtered drain water in many ways.
Follow above requirements for proper drain line setup, air gap and the need for a non-restrictive spring check valve. Allow water to
completely drain through line and do not allow drain water to sit in line. do not restrict drain water flow. do not cross-connect or tie into
to other water lines.
OUTSIDe INSTALLATION
 Install the system where it will not be exposed to direct sunlight or subject to temperatures outside of the limits stated in "Instructions
Before Using" on Page 6 in this manual. the system is weather resistant but not weather-proof and it is a requirement to protect the
system from outside elements and weather exposure.
 Follow all instructions found on Page 6 in this manual and all information, requirements, cautions and hints stated on this page.
Helpful Hint to Protect your System:
at a big box store that can be easliy assembled on site and house the system. If applicable, insulation can be applied to reduce heat
or cold. If applicable, holes can be made to run pipes, drain line and/or electrical. Any other method you choose is fine as long as the
system is protected in a similar manner. Sorry, but nice plants, trees and shrubs are not a protection method.
 Burying the System: If you choose to bury the system for aesthetic reasons, please see the requirements to prevent system damage.
REQUIRED:
Place system into a heavy-duty, corrugated, solid wall culvert pipe with a minimum diameter size 2" larger than the
diameter of the system that is being installed to prevent ground movement which can cause tank to be crushed.
REQUIRED:
Protect top portion and valve of the system that has been placed into the culvert pipe by following all information in
this section.
Helpful Hint:
A shorter shed, solid covering or a big artificial rock can be used to protect the system from the elements, pets or the
kids kicking a soccer ball into it.
If an outside installation is preferable or needed, simply purchase an inexpensive plastic shed