General Notes on Programming

6. 6. Special Function Commands

Special Function Commands allow access to specific data in the Dialer. You must be in the
programming mode to use these commands.
Commands
Data confirmation mode. After each 3 digit prefix the Dialer will display programmed
902
data. Refer to section 6.7 on page 29.
Load default data based on the value of X used in 942 918 X. Delete all other existing pro-
942 903
gramming, then reload default data. Refer to section 6.10 on page 31.
942 904
Clear all Search Tables (801-845). Refer to section 6.11 on page 31.
942 906
Enter Clone Master Mode. Refer to section 6.14 on page 33.
Return to data programming mode from data confirmation mode. Refer to section 6.8 on
907
page 30.
Load the country-specific default data based on the value of X. Delete all other existing
programming, then reloads default data. Refer to section 6.9 on page 31.
X = 0 for EuroRoute
942 918 X
X = 1 for UK
X = 2 for Italy
X = 3 for Spain
Display Power-on Counter (Displays the number of times that the Dialer has been powered
961
on since it was last
967
Display Route and Line peg data. Refer to section 6.13 on page 31.
942 968
Block Initialisation: 0 = Off, 1 = On. Refer to section 6.15 on page 34.
942 969
Reset Peg Counter
Display the Dialer serial number during local or remote modem programming. Refer to
970
section 6.16 on page 34.
980
Internal Clock Setting (MMDDHHMM). Refer to section 6.17 on page 35.
986
Quitting programming mode. Refer to section 6.18 on page 35.
987
Exit programming mode. Refer to section 6.19 on page 35.

6. 7. Data Verification (902)

Data Verification is a convenient method of confirming the contents of a Dialer's database.
Most maintainers use a PC with a modem (Figure 6.3) to confirm the Dialer's database,
however, a Digit Analyzer may also be used to accomplish database verification. Data is
displayed for each parameter entered. Data Verification does not alter the contents of the
Dialer's database.
29
Definition
X = 4 for France
X = 5 for Netherlands
X = 6 for Germany
X = 7 for Portugal
initialised). Refer to section 6.12 on page 31.
Figure 6.3 Data Verification