Line and Trunk Options

8. 15. 121 - Inter-ring Timing

When the Dialer detects incoming ringing, the ringing is validated by measuring the inter-ring
timing. For example, if the standard of incoming ringing is two seconds on and four seconds
off, the inter-ring timing is the time in which a ring burst ends and another one begins. Once
the second ring burst begins, the timer is reset.
Register
121 T
Refer to Appendix 2 for country-specific-default data.

8. 16. 122 - Repeat Call Attempt

The number of retries for a call attempt is programmable, with 15 retries being the highest
number allowed.
Register
122 T
Refer to Appendix 2 for country-specific-default data.

8. 17. 123 - Dialer Operation on Off-hook

The Dialer can be programmed to perform a variety of operations upon off-hook. The
operations are dialling direct, dialling using hot line and dialling using Search Tables.
Register
123 T
Refer to Appendix 2 for country-specific-default data.
Note 1: If 123 = 0, the Dialer will not allow emergency numbers to be dialled, nor will the
Dialer allow
initialisation or MF4 programming.
43
T = 0 for no inter-ring timing
T = 1 for 1 second
T = 2 for 2 seconds
T = 3 for 3 seconds
T = 4 for 4 seconds
T = 0 for no retries
T = 1 for 1 retry
T = 2 for 2 retries
T = 3 for 3 retries
T = 0 for immediately dial the Default Route defined
by register 124 (hot line operation)
T = 8 for using Search Tables (active Dialer)
T = 9 for dialling direct (inactive Dialer)
Description
T = 5 for 5 seconds
T = 6 for 6 seconds
T = 7 for 7 seconds
T = 8 for 8 seconds
T = 9 for 9 seconds
Description
T = 4 for 4 retries
T = 5 for 5 retries
T = 6 for 6 retries
T = 7 for 7 retries
Descriptio
T = 8 for 8 retries
T = 9 for 9 retrie
T =
for 10 retries
T = # for 15 retries