5.2 CLEANING

1. Before cleaning the pump, wear rubber gloves and protective glasses.
2. During CIP and SIP process, do not touch the pump and pipelines.
3. Ensure velocity rate of the CIP solutions is adequate to clean entire circuit. For most
applications a velocity of 1.5 m/sec is sufficient. For the CIP solution to achieve the proper
velocity, the pump drive must have enough speed range and horsepower. The required
inlet pressure also must be satisfied. If the pump does not supply enough CIP solution
velocity, a separate CIP supply pump with an installed bypass may be used.
4. Refer to the below CIP and SIP process.