INSTALLATIoN
electrical connection
11.2 Safety extra low voltage
Xd04
Terminal, safety extra low voltage
T(MK)
Mixer circuit temperature sensor for HSBC 3-HKM
(optional)
T(KUE)
Temperature sensor for area cooling (optional)
T(WW)
DHW temperature sensor
T(Puffer)
Temperature sensor, buffer cylinder
PWM
Control by WPM
Control by WPM via PWM signal
f Observe the information in the operating and installation in-
f
structions of the WPM heat pump manager.
11.3 Power supply for auxiliary heating element
Note
The "Heater terminal" (XD06.1) can only be assigned
when the optional HSBC 3-HE auxiliary heating element
is installed.
XD06.1
Heater terminal (accessories HSBC 3-HE)
56
| HSBC 300 cool | HSBC 300 L cool
11.4 Sensor installation
Note
The temperature sensor needs to be replaced on com-
bined appliance system HSBC 300 L cool with WPF /
WPF cool.
f Use the PTC temperature sensor that was included in
f
the standard delivery of the heat pump.
BT20
BT06
BN (PWM IN) BU (com.)
1
2
"+"
1
2
3
Kleinspannung
XD04
Appliances concerned:
- 238826
HSBC 300 L cool
- 232909 – 232912
WPF 04 – WPF 10
- 232915 – 232918
WPF 04 cool – WPF 10 cool
"+"
"-"
"+"
"-"
"+"
"-"
"-"
4
5
6
7
8
9
www.stiebel-eltron.com
10