Dimensions and connections 16 16.2 Hydraulic diagram 17 16.3 Wiring diagram 18 16.4 Energy consumption data 22 16.5 Data table 22 GUARANTEE ENVIRONMENT AND RECYCLING | HSBB 180 Plus (GB)|HSBB 180 S Plus (GB) www.stiebel-eltron.com...
Failure to observe this information will result in serious injury or death. WARNING Failure to observe this information may result in serious injury or death. CAUTION Failure to observe this information may result in non-seri- ous or minor injury. www.stiebel-eltron.com HSBB 180 Plus (GB)|HSBB 180 S Plus (GB)|...
Safety valve: When the pressure is high, the safety valve opens to relieve the pressure in the system. Air vent valve: Components are vented through air vent valves, e.g. pipes or indirect coil. | HSBB 180 Plus (GB)|HSBB 180 S Plus (GB) www.stiebel-eltron.com...
To facilitate and speed up your enquiry, please provide the serial manager. Please observe the heat pump manager operating and number from the type plate (000000-0000-000000). installation instructions. No.: 000000-0000-000000 MENU Made in Germany www.stiebel-eltron.com HSBB 180 Plus (GB)|HSBB 180 S Plus (GB)|...
- High limit safety cut-out STB-FB - Water softening fitting HZEA - Segmented anode - CDT 180 condensate pump and condensate pan (required for continuous cooling without dew point monitoring) | HSBB 180 Plus (GB)|HSBB 180 S Plus (GB) www.stiebel-eltron.com...
(see chapter “Preparations / Installation site”). f Use the adjustable feet to compensate for any unevenness in the floor. 1 Carrying strap 2 Washer 3 Adjustable foot 4 Pipe 5 Threaded hole www.stiebel-eltron.com HSBB 180 Plus (GB)|HSBB 180 S Plus (GB)|...
When calculating the pressure drop, take account of the flow and return lines and the pressure drop of the heat pump. The pressure drop must be covered by the available pressure differential. | HSBB 180 Plus (GB)|HSBB 180 S Plus (GB) www.stiebel-eltron.com...
Connect the DHW circulation line with the gasket, the insulat- Material losses ing bushing and the flat gasket union nut. Route the drain hose to a drain to enable water to drain freely when the safety valve is open. www.stiebel-eltron.com HSBB 180 Plus (GB)|HSBB 180 S Plus (GB)|...
In the delivered condition, the 3-way diverter valve of the mul- tifunction assembly is in its centre position, so that the heating circuit and the heat exchanger for DHW heating are filled evenly. | HSBB 180 Plus (GB)|HSBB 180 S Plus (GB) www.stiebel-eltron.com...
You must have permission to connect the appliance from the relevant power supply utility. The terminal box of the appliance is located behind the front casing (see chapter “Installation / Removing / fitting the front casing”). www.stiebel-eltron.com HSBB 180 Plus (GB)|HSBB 180 S Plus (GB)|...
Only use components which have been approved by 2.9 kW 5.9 kW 8.8 kW f Connect the electrical emergency/booster heater with the desired rating as detailed in the table. HSBB 180 S: Electrical connection single phase | HSBB 180 Plus (GB)|HSBB 180 S Plus (GB) www.stiebel-eltron.com...
Check whether the signal cable to the heat pump (bus cable) Value SETTINGS is correctly connected. HEATING ELECTRIC BOOSTER HEATER NUMBER OF STAGES | HSBB 180 Plus (GB)|HSBB 180 S Plus (GB) www.stiebel-eltron.com...
If you take the system out of use, set the heat pump manager to standby so that the safety functions that protect the appli- ance (e.g. frost protection) remain active. www.stiebel-eltron.com HSBB 180 Plus (GB)|HSBB 180 S Plus (GB)|...
(i.e. no elbows or bends) Pressure drop of each elbow or bend Connection dimensions Safety assembly connection Expansion valve end connection Expansion vessel connection, male, BSP G 1 A Tundish inlet connection Tundish outlet connection www.stiebel-eltron.com HSBB 180 Plus (GB)|HSBB 180 S Plus (GB)|...
Condensate pump fuse XE06 Earth, front panel MA10 Motor, pump, heating circuit (not assigned) AA01-X1.1 Connector, CAN A (heat pump connection) MA13 Condensate pump motor AA01-X1.2 Connector, CAN B (FET/ISG connection) | HSBB 180 Plus (GB)|HSBB 180 S Plus (GB) www.stiebel-eltron.com...
Page 19
AA01-X2.14 Connector, mixer, heating circuit 2 (X2.14.1 Mixer OPEN/X2.14.2 AA07-X71 Not assigned Mixer CLOSE) AA07-X72 Connector, CAN bus AA01-X2.15 Connector, mixer, heating circuit 3 EB01-X59 Terminal, MFG (X2.15.1 Mixer OPEN/X2.15.2 Mixer CLOSE) AA06-X27 Terminal, programming unit www.stiebel-eltron.com HSBB 180 Plus (GB)|HSBB 180 S Plus (GB)|...
Page 20
Condensate pump fuse XE06 Earth, front panel MA10 Motor, pump, heating circuit (not assigned) AA01-X1.1 Connector, CAN A (heat pump connection) MA13 Condensate pump motor AA01-X1.2 Connector, CAN B (FET/ISG connection) | HSBB 180 Plus (GB)|HSBB 180 S Plus (GB) www.stiebel-eltron.com...
Page 21
AA01-X2.14 Connector, mixer, heating circuit 2 (X2.14.1 Mixer OPEN/X2.14.2 AA07-X71 Not assigned Mixer CLOSE) AA07-X72 Connector, CAN bus AA01-X2.15 Connector, mixer, heating circuit 3 (X2.15.1 Mixer OPEN/X2.15.2 Mixer CLOSE) EB01-X59 Terminal, MFG AA06-X27 Terminal, programming unit www.stiebel-eltron.com HSBB 180 Plus (GB)|HSBB 180 S Plus (GB)|...
2 x B 16 Frequency Versions IP rating IP20 IP20 Suitable for Heat pump Heat pump Dimensions Height 1280 1280 Width Depth Height when tilted 1500 1500 Weights Weight, full Weight, empty | HSBB 180 Plus (GB)|HSBB 180 S Plus (GB) www.stiebel-eltron.com...
Page 23
This will not affect warranties issued by any importers. Environment and recycling We would ask you to help protect the environment. After use, dispose of the various materials in accordance with national regulations. www.stiebel-eltron.com HSBB 180 Plus (GB)|HSBB 180 S Plus (GB)|...
Need help?
Do you have a question about the HSBB 180 Plus and is the answer not in the manual?