Preparation
9.2.3 Separating / joining the appliance sections
Separating the appliance sections
Material losses
Unscrewing the fastening screws destroys the threads in
the insulation segment.
f To open the 3 fixing tabs, loosen the fastening
f
screws slightly but do not unscrew them completely.
Note
To make removal simpler, the insulation segments have
labelled recessed grips on the left and right.
f Remove insulation segment 1.
f
f Remove insulation segment 2.
f
www.stiebel-eltron.com
f Pull the "heating sensor" out of the buffer cylinder.
f
f Release the sensor lead from the guide groove.
f
f Disconnect the push-fit connectors of the 4 hydraulic con-
f
nections. To do this, pull the spring clips fully out with a
screwdriver.
f Pull the hydraulic connectors as indicated.
f
HSBC 300 cool | HSBC 300 L cool |