3.11 Cabling

Temperature relay
Length (KTY-cable) = 460 mm
LinMot Servo Drive
The cables must be laid in such a way that they cannot be damaged by external influences.

4 Installation and commissioning

The specified power supply to the drive unit must not be exceeded.
All intended operating modes of the linear motors must be designed in accordance with
the company's software and verified in application testing.
In order to avoid unintended use, the information on the rating plate must be complied
with.

4.1 Operating conditions

Maximum ambient temperature limits are 0 °C...50 °C
The temperature of the cooling fluid must not fall below the ambient temperature, as this
presents a risk of water condensation. See Paragraph 4.8, Liquid cooling.
Internal temperature sensor error occurs at 85 °C or 135 °C
The max. installation altitude is 2'000 m (for higher values contact LinMot) above sea
level.
From 1'000 m, derating of 1 °C per 100 m is to be considered for air cooling.
NTI AG / LinMot
Trailing Chain Cable
KS10-EX-Y-Fe/E6k-
P01-48 EX protected
ENG
EX Linear motor