Easyclean Filter; Cyclonefilter - Hardi NAVIGATOR PRO Original Instruction Book

Table of Contents

Advertisement

3 - Description

EasyClean filter

The EasyClean filter is fitted in the working zone. It has a built-in valve
that automatically closes when the filter is opened for inspection and
cleaning.
• To open filter then turn it counterclockwise and pull it up, like
shown on picture.
Beside the spray pressure gauge on the platform a EasyClean clogging
indicator is located:
Clogging indicator colour
Green indicator.
Yellow indicator.
Red indicator.

CycloneFilter

With the CycloneFilter any impurities in the spray liquid will by-pass the
filter and be recirculated back to the tank via the return flow.
Function diagram
1. Filter lid
2. From pump
3. To boom
4. Return to tank
5. Return valve
Valve (5) has three positions marked with small dots on the lever:
A. This position marked with 1 dot: There is no return flow. Position is
used when rinsing the boom if there is spray liquid in the main
tank. Also used when high spraying volume is required.
B. This position marked with 2 dots: Normal spraying position. With
return flow to prevent filter is going to be clogged when spraying.
This position is used when rinsing the boom if the main tank is empty.
C. This position marked with 3 dots: Flushing position which is used if filter is clogged. Lift and hold the lever to use this
position which largely increases return flow and flushes the filter. The pressure SmartValve must be set to "Spraying".
μ
ATTENTION! Use of position C is no guarantee for a clean filter. Always regularly do a visual inspection and cleaning
of the filter. If necessary see "10 hours service - Cyclone Filter" on page 75.
DANGER! Never open the Cyclone filter unless the suction valve
is closed and the pressure SmartValve is turned to "Main tank".
Otherwise, spraying liquid may hit you when opening the filter,
and drain from the main tank!
20
Filter status
No cleaning necessary.
It is possible to finish an ongoing spraying job and
then clean filter afterwards.
Clean EasyClean filter immediately as filter is
clogged.