Water Separator/Extraction Tank - BÖWE M12 Instruction Manual

Hide thumbs Also See for M12:
Table of Contents

Advertisement

11. Maintenance

11.5.2 Water Separator/Extraction Tank

Perform maintenance work on the water separator only when the still has cooled off.
Dispose of the process water according to the regulations in your country.
You must clean the water separator and extraction tank routinely (and always after the distillation
system has boiled over). The unit does this automatically with a fixed maintenance program P54 or
as an integrated part of the so-called multi-maintenance program P49.
Start one of the maintenance programs listed above weekly.
You can run another program at the same time as the maintenance program.
Sequence of the maintenance program:
Step 1:
Draining the water phase from the water separator into the tank (7).
Step 2:
Emptying the water separator into the distillation system (6) with the solvent pump.
Step 3:
Rinsing the water separator with solvent from the clean tank (5).
Step 4:
Emptying the water separator into the distillation system (6) with the solvent pump.
Step 5:
Draining the water phase from the extraction tank into the tank (7).
Step 6:
Emptying the extraction tank into the distillation system (13) with the solvent pump.
Step 7:
Rinsing the extraction tank with solvent from the clean tank (11).
Step 8:
See step 6
Step 9:
Produce the recipient tank in the extraction tank.
Step 10:
Bring recipient tank to defined level.
After the maintenance has completed, the horn sounds and the program ends. The cycle counter is
reset to 0.
General function at the end of a cleaning cycle:
If the sensors (4 or 10) reports the level, the water phases from the safety separator and extraction
tank are drained into the process water tank when the loading door is opened.
78
11.
M12/M15/M18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M15M18

Table of Contents