Technical Specifications - BÖWE M12 Instruction Manual

Hide thumbs Also See for M12:
Table of Contents

Advertisement

4. Technical Specifications

Machine
Heating
Filling quantity
Cage volume
Cage diameter
Cage depth
Load diameter
Cleaning speed/drying speed
Spinning speed:
Max. g-factor.
Low level
High level
Operating load (max. at 400 V,50Hz)
Without distillation
With distillation
Connected loads:
Compressor capacity
Fan capacity HLL /NLL
Solvent pump capacity
Cage drive capacity
Filter drive capacity
Vacuum pump capacity
Steam generator capacity
Dimensions:
Machine:
Width:
Slimline
Crossline
Depth:
Slimline
Crossline
Height inc. trough
Height inc. trough without fan motor
Floor space: Slimline
Crossline
Filling volumes:
Tank I
filling
Tank II
filling
Tank III
filling
Economy filter 1
Economy filter 2
Distillation
filling
Cartridge filter
Jumbo Cartridge Filter
The dimensions given may differ if special options are used
12
kg (lb)
12 (26.5)
l/ US gal
240 (63.4)
mm (in)
820 (32.3)
mm (in)
460 (18.1)
mm (in)
400 (15.7)
RPM
RPM
l/ US gal
l/ US gal
60 (15.8)
kW
kW
kW
kW
2.5 /1.85
kW
kW
kW
kW
kW
mm(in)
1080(42.5)
mm(in)
1840(77.4)
mm(in)
2165(86.0)
mm(in)
1406(55.3)
mm(in)
2257(89.0)
mm(in)
1995(78.5)
2
2
m
(ft
)
2.3(24.8)
2
2
m
(ft
)
2.5(26.9)
l/ US gal
120 (31.7)
l/ US gal
80 (21.2)
l/ US gal
90 (23.7)
l/ US gal
40 (10.6)
l/ US gal
40 (10.6)
l/ US gal
120 (31.7)
l/ US gal
l /US gal
40 (10.5)
4.
M12
Steam
Electric
12 (26.5)
240 (63.5)
820 (32.3)
460 (18.1)
400 (15.7)
35
600
165
30 (7.9)
30 (7.9)
60 (15.8)
7
8
4.0
2.5 /1.85
1.1
3.7
0.55
0.37
-
10 /8.5
1080(42.5)
1840(77.4)
2165(86.0)
1406(55.3)
2257(89.0)
1995(78.5)
2.3(24.8)
2.5(26.9)
120 (31.7)
80 (21.2)
90 (23.7)
40 (10.6)
40 (10.6)
120 (31.7)
15 (6.6)
15 (6.6)
40 (10.5)
M12/M15/M18
M12
35
600
165
16
27
4.0
1.1
3.7
0.55
0.37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M15M18

Table of Contents