11. Maintenance

Attention: Warranty claims will only be accepted if maintenance has been performed
properly! Follow safety regulations! All recommendations concerning
maintenance are minimum requirements and refer to a one-shift operation!

11.1 Operation and Maintenance Summary

When starting operation:
Turn on steam supply
Turn on room ventilation system
Turn on cooling water supply
Turn on compressed air supply
Open condensate valve
Turn on machine main switch
Start deodorizing program P43, press "STOP"
button when program ends and
signal sounds.
When stopping operation:
Turn off machine main switch
Turn off steam supply
Close condensate valve
Turn off cooling water supply
Turn off compressed air supply to compressor
Turn off room ventilation system or switch to
night operation
Inspection and maintenance work:
Daily:(before starting the first cycle)
Check machine for leaks
Check solvent safety trough for solvent
Drain water from compressed air armature
Clean button trap strainer and lint filter (see
11.5.1)
Dispose of process water in accordance with
the regulations that apply in your country!
Check the liquid level of the cleaning agent
container
Machine is ready for operation
Daily: (after the last cycle)
Execute distillation maintenance program P45
(Alternatively start with 15 E during the last
charge)
66
Weekly:
Run multi-maintenance program P49 or run
alternative P46, P54 and P45
Clean the sprayer dirt strainers and
spray nozzles
Check limit switch function
Unbalance switch: Visual inspection for
damage. Check the central position of the
feeler in the Bore.
Monthly:
Execute multi-maintenance program P50
Check solvent levels in the tanks
Clean strainers in water and steam feeders
Lubricate cage bearing
Semi-annually:
Have the flash point of the solvent checked
Check air cooler, clean
Clean tanks
Retighten screwed unions
Check V-belt tension, re-tension
Annually:
Machine inspection (according to
BGR 500 chapter 2.14)
Remove filter discs and clean in the
machine (program P6)
Check back wall of cage, clean
Attention:
Immediately close the loading door
and maintenance openings again.
Use only lithium-based lubricating
greases, such as.
- ALVANIA 3 (SHELL)
- BEACON 2 (ESSO)
11.
11.1
- MARSON L2 (FINA)
- LGMT 3 (SKF)
M12/M15/M18