5

Settings and Optimum Operating Values

Machine
Basic value:
Steam pressure (saturated steam)
Steam temperature (max. permitted)
Cooling water pressure
Low cooling water level switch
Cooling water temperature, max.
Compressed air
Low air pressure switch (if present)
Cage speeds:
Cleaning / drying
Spinning
Reversing cycle (cleaning)
Low level
High level
Pump pressure (max.)
Filter surface, economy filter
Tank I: optimum filling volume (high level)
Tank III: optimum filling volume
Detergent solution cooler:
Detergent solution thermal sensor:
Detergent solution cooler ON
Alarm value
Refrigeration technology:
Filling capacity, cooling agent R 404A
Expansion valve:
Nozzle size:
solvent cooling
Drying /reduction
High pressure control switch ON
High pressure control switch OFF
Drying:
Cooling water regulator setting:
Adjust 4 – 6 min. after start of drying
Temp. sensor, cage entry (gentle drying)*
Temp. sensor after cooler:
Alarm value, 1
Alarm value, 2
Safety temperature limiter after cooler:*
Safety temperature limiter cage inlet:*
* at flash point >55°C (131°F)
21
bar(psi)
4–5(58–72.5)
°C(°F)
150(302)
bar(psi)
2-4(29-58)
bar (psi)
°C(°F)
bar(psi)
bar (psi)
RPM
RPM
400 /600
sec.
l(US gal)
l(US gal)
bar(psi)
2
2
m
(ft
)
2.4(34.8)
l(US gal)
l(US gal)
°C(°F)
°C (°F)
kg(lb)
4.6(10.1)
no.
no.
bar(psi)
bar(psi)
bar(psi)
°C(°F)
°C(°F)
°C(°F)
°C(°F)
°C(°F)
100 (212)
M12
M15
4–5(58 – 72.5)
150(302)
2-4(29-58)
2 (29)
2 (29)
25(77)
25(77)
6(87)
6(87)
4 (58)
4 (58)
35
400/600
10/1/10
10/1/10
30(7.9)
35(9.2)
60(15.8)
75(19.8)
1.5(22)
1.5(22)
2.4(34.8)
60(15.8)
75(19.8)
60(15.8)
75(19.8)
40(104)
40(104)
45 (113)
45 (113)
4.6(10.1)
03
01
21(304)
21(304)
25(362)
25(362)
18(261)
18(261)
75(167)
75(167)
30(86)
30(86)
35(95)
35(95)
45 (113)
45 (113)
100 (212)
M12/M15/M18
5
35
03
01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M15M18

Table of Contents