7.1 Tanks

The work tank contains solvent, which is used over and over.
The solvent is pumped from the work tank to the cage. If there is not enough solvent in the work
tank, fresh solvent is taken from the clean tank. After the garments have been cleaned, the solvent is
pumped back to the work tank or to the distillation.
Tank 3 is an extra tank for special applications. If an optional second centrifuge filter is used, this is
allocated to the third tank. This permits separate cleaning of light and dark products.
Clean solvent that is recovered from the 2
clean tank overflows, it fills up the work tank again.
Sacrificial anodes in the tanks protect against corrosion.
M12
Work tank
Tank 3
Clean tank
M15
Work tank
Tank 3
Clean tank
M18
Work tank
Tank 3
Clean tank
All three tanks are self-cleaning, which means that the sloping bottoms remain nearly free of dirt.
1 = work tank
2 = clean tank
3 = tank 3 (extra tank)

7.2 Solvent Pump

The solvent pump is a self-priming vertical pump.
Delivery rate up to 175 l/min (46.2 US gal/min)
34
nd
fraction of the distillation is in the clean tank. When the
Filling volumes
120 l (31.7 US gal)
90 l (23.7 US gal)
80 l (21.2 US gal)
Filling volumes
145 l (38.3 US gal)
90 l (23.7 US gal)
95 l (25.1 US gal)
Filling volumes
170 l (44.9 US gal)
90 l (23.7 US gal)
110 l (29 US gal)
Recommended filling quantity
60 l (15.8 US gal) (high level)
60 l (15.8 US gal) (high level)
80 l (21.2 US gal)
Recommended filling quantity
75 l (19.8 US gal) (high level)
75 l (19.8 US gal) (high level)
95 l (25.1 US gal)
Recommended filling quantity
90 l (23.8 US gal) (high level)
90 l (23.8 US gal) (high level)
110 l (29 US gal)
7.
7.1
707766-04-0
7.2
M12/M15/M18