Advertisement

5
Appendix
5.1

How to check the specification change

Check the SERIAL number indicated on the inverter rating plate or packaging. For how to read the SERIAL number, refer to
page
12.
5.1.1

Specification change

 Number of connectable units on the CC-Link IE Field Network Basic
Number of connectable units
Master: 1
Slave: up to 16 stations (16 stations × 1 group)
Master: 1
Slave: up to 16 stations (16 stations × 4 groups)
 Functions available for the inverters manufactured in May 2020 or later
Item
Mitsubishi Electric geared motor
Plug-in option
Stand-alone option
Added parameters
Changed parameter setting range
 Functions available for the inverters manufactured in August 2020 or
later
Item
Mitsubishi Electric vector control dedicated
motor (SF-V5RU (1500 r/min series))
Plug-in option
Added parameters
Changed parameter setting range
Added fault signals
98
5. Appendix
5.1 How to check the specification change
SERIAL (serial number)
□□ 204 ○○○○○○ or earlier
□□ 205 ○○○○○○ or later
GM-[], GM-[]P
FR-A8ND E kit, FR-A8NP E-kit
Parameter unit (FR-PU07), LCD operation panel (FR-LU08)
Pr.1499, P.E107, (Pr.75)
• Setting value "13" added for Pr.52, Pr.54, Pr.158, Pr.774 to Pr.776, Pr.992, Pr.1027 to
Pr.1034
• Setting values "1800 and 1803" added for Pr.71 and Pr.450 (for 200/400 V class only)
• Setting values "10000 to 10003, and 10014 to 10017" added for Pr.75 (for the safety
communication model only)
The SF-V5RU 1.5 to 5.5 kW motors can be driven by the FR-E820-0110(2.2K) to 0330(7.5K)
inverters.
The SF-V5RUH 1.5 to 5.5 kW motors can be driven by the FR-E840-0060(2.2K) to 0170(7.5K)
inverters.
FR-A8AP E kit
Pr.284, Pr.359, Pr.367, Pr.368, Pr.369, Pr.376, Pr.422, Pr.552, Pr.600 to Pr.604, Pr.607,
Pr.608, Pr.690, Pr.692 to Pr.696, Pr.802, Pr.823, Pr.828, Pr.833, Pr.840 to Pr.848, Pr.854,
Pr.873, Pr.877 to Pr.881, P.A107 (Pr.285)
• Setting value "8888" added for Pr.11
• Setting value "35" added for Pr.52, Pr.774 to Pr.776, Pr.992, Pr.1027 to Pr.1034
• Setting values "30 and 33" added for Pr.71 and Pr.450
• Setting value "2" added for Pr.95
• Setting values "13, 23, 42, 43, and 74" added for Pr.178 to Pr.189
• Setting values "30 to 33, and 130 to 133" added for Pr.190 to Pr.196
• Setting values "30 to 32" added for Pr.320 to Pr.322
• Setting value "33" added for Pr.320 to Pr.322 (for the Ethernet model and the safety
communication model only)
• Setting values "0 to 2, and 9" added for Pr.800
• Setting value "2" added for Pr.850
• Setting value "6" added for Pr.858
• Signal loss detection (E.ECT)
• Brake sequence fault (E.MB1 to E.MB3)
Details
Details