Appendix2 Specification Change Check; Appendix 2-1 Changed Function - Mitsubishi Electric FR-D720-0.4K Instruction Manual

Hide thumbs Also See for FR-D720-0.4K:
Table of Contents

Advertisement

Appendix2

Appendix 2-1 Changed function

(1)
Addition of output signal for the safety function
The change applies to the February 2009 production or later.
Output of safety monitor output signal 2 (SAFE2) is enabled by setting "81 or 181" to any of Pr.190, Pr.192, Pr.197
(Output terminal function selection). (Refer to page 120)
The function of terminal SO is set by Pr.197 SO terminal function selection. (Refer to page 120)
Terminal SO can be turned ON/OFF by setting Pr.496 Remote output data 1. (Refer to page 127)
(2)
Changed operating conditions of the SAFE and SAFE2 signals and addition of the terminal SO monitor
The change applied to the January 2012 production or later.
E.CPU has been added to the operating conditions of the SAFE and SAFE2 signals used in the safety stop function.
(Refer to page 27)
Monitoring of the terminal SO, which is an I/O terminal, has become available on the operation panel. (Pr.52 = "55").
(Refer to page 132)
The terminal SO monitor has been assigned to the output terminal monitor bit 7 of RS-485 communication (Mitsubishi
inverter protocol, Modbus-RTU protocol). (Refer to page 196, 208)
The SO signal (Pr.197) has been assigned to the inverter status monitor (extended) bit 9 of RS-485 communication
(Mitsubishi inverter protocol). (Refer to page 197)
The SO signal (Pr.197) has been assigned to the inverter status bit 9 of the RS-485 communication (Modbus-RTU
protocol). (Refer to page 208)