Mitsubishi Electric 800 Series Instruction Manual page 35

Compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Ethernet model
Sink logic
Main circuit terminal
Control circuit terminal
MCCB
Three-phase
AC power
supply
Control input signals (No voltage input allowed) 
Contact input common
24VDC power supply(Common for
external power supply transistor)
Safety stop input common
Safety stop input (Channel 1)
Safety stop input (Channel 2)
Frequency setting signals (Analog)
Connector for
plug-in option connection
*1
Remove the jumper between P1 and P/+ to connect the DC reactor.
*2
The function of these terminals can be changed using the Input terminal function selection (Pr.178 to Pr.179). (Refer to the FR-E800 Instruction
Manual (Function).)
*3
The initial setting varies depending on the specification.
*4
Terminal input specifications can be changed by analog input specification switchover (Pr.73, Pr.267). To input voltage, set the voltage/current
input selection switch to "V". To input current, set the switch to "I". The initial setting varies depending on the specification. (Refer to the FR-E800
Instruction Manual (Function).)
*5
It is recommended to use 2 W 1 kΩ when the frequency setting signal is changed frequently.
*6
The function of these terminals can be changed using the Pr.192 ABC terminal function selection.
34
2. Installation and Wiring
2.4 Terminal connection diagrams
Earth
(Ground)
MC
R/L1
S/L2
T/L3
Earth
(Ground)
Forward
rotation start
Reverse
rotation start
PC
S1
S2
Shorting wire
3
Frequency
setting
2
potentiometer
1/2W1kΩ

1
Terminal 4 input
(+)
(-)
(Current input)
Voltage/current
input switch
DC reactor

R
PR N/-
Jumper
P1
P/+
Main circuit
Control circuit
DI0
DI1
SINK
SOURCE
SINK

SD
SOURCE
24V
Output
shutoff
circuit
Ethernet
10(+5V)
connector
2 0 to 5VDC
Ethernet
0 to 5VDC

connector
0 to 20mADC
USB mini B
5(Analog common)
connector
4 4 to 20mADC
0 to 5VDC

0 to 10VDC
2
V
I
4

Option connector
V
W
C
B
Relay output
(Fault output)
A
SO
Safety monitor output
SOC
Safety monitor output common
Motor
M
Earth (Ground)
Relay output 
Safety stop signal