Gain/Filter Setting Servo Parameters Group ([Pr. Pb; [Pr. Pb82_Position Command Smoothing Filtering Time Constant (Pft)] - Mitsubishi Electric MELSERVO-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 Series:
Table of Contents

Advertisement

7.2
Gain/filter setting servo parameters group ([Pr.
PB_ _ ])
[Pr. PB82_Position command smoothing filtering time constant
(PFT)]
Initial value
0.0 [ms]
Set the position command smoothing filtering time constant.
This servo parameter can be used when [Pr. PB81.4 Position command smoothing filter] is set to "1" (enabled).
7 SERVO PARAMETERS
68

7.2 Gain/filter setting servo parameters group ([Pr. PB_ _ ])

Setting range
0.0 to 100.0
Setting method
Each axis