Intended Use - Beckhoff ELX1052 Operating Manual

Two, four and eight channel digital input terminals for namur sensors, ex i
Hide thumbs Also See for ELX1052:
Table of Contents

Advertisement

Product overview
Technical data for explosion protection ELX1052-0000
Ex marking
Certificate numbers
Power supply
Field interfaces
Reactance
(without consideration of the
simultaneousness)
2.5

Intended use

Endangering the safety of persons and equipment!
The ELX components may only be used for the purposes described below!
Observe ATEX and IECEx!
The ELX components may only be used in accordance with the ATEX directive and the IECEx scheme!
The ELX terminals extend the field of application of the Beckhoff bus terminal system with functions for
integrating intrinsically safe field devices from hazardous areas. The intended field of application is data
acquisition and control tasks in discrete and process engineering automation, taking into account explosion
protection requirements.
The ELX terminals are protected by the type of protection "Increased safety" (Ex e) according to
IEC 60079-7 and must only be operated in hazardous areas of Zone 2 or in non-hazardous areas.
The field interfaces of the ELX terminals achieve explosion protection through the type of protection "intrinsic
safety" (Ex i) according to IEC 60079-11. For this reason, only appropriately certified, intrinsically safe
devices may be connected to the ELX terminals. Observe the maximum permissible connection values for
voltages, currents and reactances. Any infringement can damage the ELX terminals and thus eliminate the
explosion protection.
The ELX terminals are open, electrical equipment for installation in lockable cabinets, enclosures or
operating rooms. Make sure that access to the equipment is only possible for authorized personnel.
Ensure traceability!
The buyer has to ensure the traceability of the device via the Beckhoff Traceability Number (BTN).
16
II 3 (1) G Ex ec [ia Ga] IIC T4 Gc
II (1) D [Ex ia Da] IIIC
I (M1) [Ex ia Ma] I
IECEx BVS 18.0005X
BVS 18 ATEX E 005 X
Invariable in connection with ELX9560
U
= 10.75 V
O
I
= 12.0 mA
O
P
= 33 mW
O
linear
L
0
Ex ia I
100 mH
Ex ia IIA
100 mH
Ex ia IIB
100 mH
Ex ia IIC 100 mH
Ex ia IIIC 100 mH
WARNING
CAUTION
CAUTION
Version: 2.0.0
ELX1054-0000
ELX1058-0000
U
= 10.72 V
O
I
= 10.4 mA
O
P
= 28 mW
O
linear
C
L
0
0
58 µF
100 mH
66 µF
100 mH
15 µF
100 mH
2.14 µF
100 mH
15 µF
100 mH
ELX1052, ELX1054 and ELX1058
C
0
58 µF
66 µF
15 µF
2.14 µF
15 µF