ENTER/EXIT PROGRAMMING MODE
2D Maximum Decoding Time
This feature specifies the maximum amount of time the software will spend attempting
to decode a 2D label. The selectable range is 10 milliseconds to 2.55 milliseconds.
$CDETM0A
2D Maximum Decoding Time = 200 msec
$CDETM23
2D Maximum Decoding Time = 500 msec
$CDETM64
2D Maximum Decoding Time = 2 Seconds
$CDETMFF
206
GRYPHON™ I GD/GBT/GM4500
2D Maximum Decoding Time = 100 msec
$CDETM14
2D Maximum Decoding Time = 350 msec
$CDETM32
2D Maximum Decoding Time = 1 Second
$CDETMC8
2D Maximum Decoding Time = 2.55 Seconds
2D SYMBOLOGIES