Troubleshooting - Belling GTG 60 Series User Manual

Hide thumbs Also See for GTG 60 Series:
Table of Contents

Advertisement

Trouble shooting
Repairs should be performed by a licensed technician only. Improper repair may result in
considerable danger to you and others.
However, some minor problems can be resolved as follows:
Problem
No ignition
Poor ignition
Strange noises when
gas is burning
Flame cuts out
Yellow flame (on
natural gas)
Unstable Flame
Smell of unburnt gas,
even when the knobs
are returned to the off
position.
Probable cause
No Spark.
The burner caps and skirts are not
correctly assembled.
The gas tap is closed.
The gas tap is not completely
open.
The burner caps and skirts are not
correctly assembled.
Debris on the spark plug ceramic sleeve.
The burners are wet.
The holes in the burner skirt are clogged.
The burner caps and skirts are not
correctly assembled.
If there is continuous clicking, check
whether the burner parts and spark plugs
have got wet - let them dry out. Check that
control knobs are not stuck down. Do not
touch a spark plug while it is sparking.
The flame supervision device is
contaminated with alien substance.
A pan has boiled over and extinguished the
flame.
A strong draught may have blown
the flame out.
The holes in the burner skirt are clogged.
The hob has not been converted to the
type of gas available.
The burner caps and skirts are not
correctly assembled.
Gas leakage
Turn the burner control knob to
the off position. Wait at least 1
Please turn off zone and check
Check the type of gas available.
Turn the gas off at the isolation
valve at the gas meter. Do not
turn any electrical switches on
or off. Do not use any sources of
emergency service on 0800 111
999 from outside the property.
11
Solution
Check the electricity supply.
Assemble them correctly.
Open the gas tap completely.
Open the gas tap completely.
Assemble them correctly.
Wipe the spark plug ceramic
sleeve with a dry cloth.
Dry the burner parts carefully.
Clean the burner skirt.
Assemble them correctly.
Clean the flame supervisory
device probe
minute before attempting to
reignite the burner.
cooking area for draught such
as open windows. Wait one
minute and reignite zone.
Clean the burner skirt.
Assemble them correctly.
ignition. Open doors and
windows to ventilate the
property. Call the gas

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents