Alert and Alarm Scenarios

The following pages describe the most likely alerts and alarms:
Alarm Type
Display
Low-Level
Cycle
Over
Current
System
Fault
3A6714C
What it Indicates
There is a low-level of lubricant in
the reservoir
The cycle was not completed in 4
minutes.
The measured motor current is
above the maximum operating level.
The motor turns off and a new lube
cycle is not allowed to be initiated.
An internal fault has occurred.
The controller may not be recover-
able from this state.
Solution
Add lubricant to reservoir.
An alert will auto-clear.
An alarm must be reset by
pressing and holding the
Cancel Button for 4 sec-
onds.
Check for a plugged or broken line, or
other component failure such as a divider
valve.
An alert will auto-clear.
An alarm must be reset by
pressing and holding the
Cancel Button for 4 sec-
onds.
Check to make sure that the system is
operating correctly. A blocked line could
create excessive motor current.
Examine the pump to verify it is rotating
properly.
An alarm must be reset by
pressing and holding the
Cancel Button for 4 sec-
onds.
Attempt a power cycle of the device.
If the alarm does not clear, contact Graco
Customer Service.
Alerts and Alarms
27