Alerts and Alarms

Alert and Alarm Scenarios

The following pages describe the most likely alerts and alarms:
Alarm Type
Display
Low-Level
Cycle
Over
Current
System
Fault
24
What it Indicates
There is a low-level of lubricant in
the reservoir
The cycle was not completed in the
amount of configured time.
The measured motor current is
above the maximum operating level.
The motor turns off and a new lube
cycle is not allowed to be initiated.
An internal fault has occurred.
The controller may not be recover-
able from this state.
Solution
Add lubricant to reservoir.
An alert will auto-clear.
An alarm must be reset by
pressing and holding the
Cancel Button for 4 sec-
onds.
Check for a plugged or broken line, or
other component failure such as a divider
valve.
An alert will auto-clear.
An alarm must be reset by
pressing and holding the
Cancel Button for 4 sec-
onds.
Check to make sure that the system is
operating correctly. A blocked line could
create excessive motor current.
Examine the pump to verify it is rotating
properly.
An alarm must be reset by
pressing and holding the
Cancel Button for 4 sec-
onds.
Attempt a power cycle of the device.
If the alarm does not clear, contact Graco
Customer Service.