Armstops
Install armstops for both arms at the rear beam.
Install them equal on both sides so they meet the
liftarms at the same time. The stops must reach as
high up as possible on the liftarm.
See picture 14.
Pict. 14
Transport lock
For CE marked lifts with 1000kg max lifting capacity
and over ZEPRO provides platforms without trans-
port lock. For other lifts transport lock are installed
on the platforms right side.
Electric safety valves can serve as transport locks
for platforms. The lock opens automatically when the
down button of the control unit is pressed.
The valves are one-way valves which allow oil to
flow into the cylinders but not out from them unless
current has been supplied to them via the lowering
valves. The platform is hence hydraulically locked
under transport.
Bleeding the cylinders
For all lift cylinder models.
Fully lower the platform a few times. You may have to
lift the truck to fully lower the platform.
Concerning tiltcylinder models
Tilt cylinder can be purged of air by closing the platform
up against the vehicle body abd then opening and tilting
all the way down.
8. Installation, continued
Hydraulic Automatic Tilt
When hyd. auto-tilt is installed the angle sensor should
be installed on the lift arm as in the diagram