On main switch of either Energier pro bi-directional inverter or RCF remote, you can set the unit under charger only mode. This function was designed
for mobile or marine application, in case you parked your vehicle or boat for a period of time without operation. Under this mode, in case of mains failure
or cut off, the Energier pro bi-directional inverter will not switch on inverter mode. With this function, it can protect your battery to be discharged under
unintentionally power cut out.
2.20 RS485 communication
RS485 / MODBUS was offered in this port. It can be connected to the Vision Lite or Rapconfig .
2.21 Software configuration
Energier pro bi-directional inverter was fully programmable through PC of following parameters:
Battery charging parameters
AC input range
Switching parameters
Battery configuration : capacity, type and low voltage protection level
AC source rated current
Working mode
Dry contact configuration
2.22 Comprehensive Protection
The equipment is being protected against many failures through hardware and software making it robust and reliable.
Overload protection
Both of charger and output are being protected against overload by software.
In case of the Energier pro bi-directional inverter is too long or too heavily overloaded, it will switch off. After 60secs, it will switch on automatically.
In case of 3times overload shutdown, it will not switch on automatically. In this case, you need to manually switch on Energier pro bi-directional inverter.