Slave Charger; Transfer - TBB Energier Pro Series User Manual

Bi-directional inverter
Hide thumbs Also See for Energier Pro Series:
Table of Contents

Advertisement

Voltage compensated charging
Through separately installed VS (battery voltage sensor), Energier pro bi-directional inverter could automatically adjust its output
compensating the voltage drop on the cable assuring the full charging through delivering the right voltage to battery.
Charger capacity adjustable
Through the clock switch at central panel or through Vision Lite or Rapconfig, the user can choose the capacity of batteries they want
to charge. Depending on the selection, Energier pro bi-directional inverter will automatically adjust its output power making it suitable
for the battery capacity selected. The charging current default threshold rate is 15% of the battery capacity (I =0.15C) chosen.
Lithium battery charging
Energier pro bi-directional inverter can be configured to charge Lithium battery and charging parameter can be programmed as well
through Vision Lite or Rapconfig.

2.4 Slave Charger

Along with a powerful charger for stationery/service battery, Energier pro bi-directional inverter also offers a slave charger which is a
3-5A floater charger(Only for 12VDC / 24VDC model without CF5090M).For mobile application, it can be used for on board starter
battery charging.

2.5 Transfer

When voltage/frequency/waveform of external AC input matches the minimum quality, the voltage will be switched directly to AC output.
Energier pro bi-directional inverter will switch off, battery charger will switch on and any loads connected will be powered by external AC
input. You will have the same voltage on the AC output as AC input.
In case of AC input source failure or exceeding the minimum requirement, Energier pro bi-directional inverter will initiate a quick switching
to inverter (about 15ms), of which will guarantee an undisturbed power for the majority of appliances. Once AC input resumes or matches
the quality, the unit will switch back again within 15ms. In this mode, Energier pro bi-directional inverter could be used as an UPS. Energier
pro bi-directional inverter can also be configured to solar mode (DC priority), please refer to 2.10.
5
Energier pro User Manual