Weak Grid Mode; Solar Mode; Low Voltage Disconnect (Lvd) - TBB Energier Pro Series User Manual

Bi-directional inverter
Hide thumbs Also See for Energier Pro Series:
Table of Contents

Advertisement

Please refer to following chart for all setting of DIP Switch:
1
DIP Switch

Weak Grid Mode

4.2 Weak Grid mode
Using DIP Switch 1, you can set the system in weak grid mode. Please refer to chapter 2.9 for explanation.
This configuration will adjust the minimum voltage of AC input which Energier pro bi-directional inverter will qualify
and pass through to your AC appliance. Majority of present appliance will work properly. However, before perform
this configuration, please double check the electrical rating of connected load. Low voltage might cause damage for
particular load.

4.3 SOLAR mode

Through DIP Switch 2, you could configure the system in solar mode. For explanation, please refer to chapter 2.10.

4.4 Low Voltage disconnect (LVD)

Through the DIP Switch 3, you can configure the premium low voltage protection level for your system. Following please find
following the data.
The following DOD is ONLY estimation. The exact measure of the battery SOC is almost impossible with only electrical parameter.
It may vary according to discharge current, battery healthy etc.
DS3
12 VDC model
off
on
The default setting was OFF, 10.5 VDC (12 V model) / 21VDC (24 V model) / 42 VDC (48 V model).
2
3
Solar Mode
LVD
24 VDC model
10.5 VDC
21.0 VDC
11.7 VDC
23.4 VDC
4
5
6
Battery Type
EQ
48 VDC model
est DOD
42.0 VDC
>90%
46.8 VDC
ab. 60%
26
Energier pro User Manual
7
8
P.S.
GEN Mode
recommendation
mobile
solar or backup