9.Trouble Shooting

9.1 LED indicator on front panel and audible alarm

√ : ON x : OFF
Status
Function
Constant
current
Charge
Constant
Function
voltage
Float
Stop
charging
EQ
Inverter ON
Inverter
Power
Save mode
Battery
low voltage
Battery
overvoltage
Inverter
overload
Alarm
Inverter
Mode
overtemp
Bypass
overtemp
Over charge
AEA limited
Fan block
Battery
overvoltage
Protection
Battery
mode
low voltage
Inverter
overload
overtemp
Charger
fault
Shortcut
Bypass Charger Inverter Charging Charged PS mode
×
×
×
×
×
×
×
×
flash
×
×
×
×
×
×
×
×
×
×
×
×
flash
×
flash
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
LED on front panel
×
×
flash
×
×
×
×
×
×
×
flash
flash
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
46
Energier pro User Manual
Over temp
Over load
Fault
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
flash
×
×
flash
×
×
flash
×
flash
×
flash
×
flash
×
×
flash
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Audible
alarm
×
×
×
×
×
×
×
beep 0.5s
every 5s
beep 0.5s
every 1s
beep
continuously
beep
continuously