List Of Parameters - Riello INSIEME EVOe 32 B/110 LN Installation And Maintenance Manual

Hide thumbs Also See for INSIEME EVOe 32 B/110 LN:
Table of Contents

Advertisement

2.17 List of parameters

9
The programming lines can be hidden, according to the access level (User, Installer) and to
the thermal unit configuration.
9
The parameters of Installer level must be changed only by the Technical Assistance Service
R
.
Key:
DHW Domestic hot water
HT
High temperature direct circuit
BT
Low temperature mixed circuit
DCW
Domestic cold water
Par.
Menu
Description
No.
Quick adjustment of direct Zone/Zone 1 heating set-
point in 0 and 3 heating modes.
By connecting the zone control accessory, this pa-
0000
013
rameter can be used to quickly change direct Zone/
Zone 1 setpoint. This parameter simultaneously mod-
ifies the value of Par. 2103.
Quick adjustment of Zone 2 heating setpoint in 0 and
3 heating modes.
By connecting the zone control accessory, this
0000
023
parameter can be used to quickly change Zone 2
setpoint. This parameter simultaneously modifies the
value of Par. 2203.
Quick adjustment of Zone 3 heating setpoint in 0 and
3 heating modes.
By connecting the zone control accessory, this
0000
033
parameter can be used to quickly change Zone 3
setpoint. This parameter simultaneously modifies the
value of Par. 2303.
0000
047
Quick adjustment of DHW setpoint with heater
Quick adjustment of DHW setpoint with instant pro-
0000
048
duction
Test mode
0000
200
0 = Function disabled
1= Function active
Stops the venting function
0000
201
0 = No action
1 = Stop venting
Unit of measurement for temperature
0000
901
0 = °C
1 = °F
Pressure unit of measurement
0000
902
0 = BAR
1 = PSI
1000
1101
Direct Zone/Zone 1 delivery temperature
1000
1102 Direct Zone/Zone 1 ambient temperature
1000
1201 Zone 2 delivery temperature
1000
1202 Zone 2 ambient temperature
1000
1301 Zone 3 delivery temperature
1000
1302 Zone 3 ambient temperature
1000
1001 CH flow temperature
1000
1002 Domestic hot water temperature
1000
1003 Domestic cold water temperature
1000
1004 Outdoor temperature
1000
1007 Return temperature
1000
1033 System pressure
1000
1032 Error code
1000
1112
Zone 1 heating setpoint
1000
1113
Zone 2 heating setpoint
1000
1114
Zone 3 heating setpoint
OT
OpenTherm
SA
Ambient probe
SE
Outdoor sensor
TA
Room thermostat
Range
Main menu
See Par. 2103
See Par. 2203
See Par. 2303
See Par. 2047
See Par. 2048
0...1
0...1
0...1
0...1
Info menu
31
INSTALLATION
Access level:
U:
End user
I:
Installer
Default setting
Ac-
INSIEME EVOe 32
UM
cess
B/110 LN
See Par. 2103
°C
See Par. 2203
°C
See Par. 2303
°C
°C
°C
0
0
0
0
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
bar
°C
°C
°C
U
U
U
U
U
I
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U