2.7 Assembling the flue collar
1
- 6000-022130
- 1913-018991
2.8 Setting up the insert
The entire convection box with the combustion
chamber in must be adjusted in height using
adjusting screws. FIG. 1.
Remove the stones and the 4 gaskets in the
combustion chamber - see page 12, and adjust
through the holes in the bottom of the combu-
stion chamber.
1
2
The flue collar (6000-022130) is mounted
from inside the stove's combustion chamber
with 4 x M6x20 (0008-1114).
Make sure the insert is level.
It must be ensured that the 4 gaskets lie just
above the holes before the bottom stones are
put back in place. FIG. 2