8 stove is exempt for use in smoke control areas when burning dry wood Pending www.heta.dk Danish DesiGn . Danish QUality . Danish ProDUCtion...
Signed on behalf the manufacturer of _____________________________________ Lemvig 05-10-2016 Lars Kirk HOD ____________________________________________________________________________________________________________________ In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid. Heta A/S, Jupitervej 22, DK-7620 Lemvig, Tlf. +45 9663 0600, www.heta.dk Page 1 of 1...
Heta stove. Especially if you follow the following advice and instructions. Scan-Line 8 wood stove is approved according to EN 13240, NS 3058, NS 3059 and A15 Østrig. These approvals, means that the wood stove meets a variety of specifi- cations and requirements, ensuring it is made of quality materials, minimum environ- mental impact and that it has an optimum fuel economy.
It is important that upon receipt check your Heta product completely and report any damage or defects to your dealer. The packaging must be disposed of as follows: Wood is untreated and able to burn in the stove.
Page 5
With your new wood stove you should find the following: Q.C. check Operating / Instruction manual Data plate Heta glove 8056-0000-DK DOP-Scan-line 8 -XXXX-2016 Heta A/S Jupitervej 22 7620 Lemvig Denmark Produktions år: 2016 DS/EN 13240, AEA, NS 3058/3059, Aus §15A Produkt beskrivelse Produktionsnummer Scan-line 8 brændeovn...
1.2 first firing from use in a wood stove. Heta wood stoves are, treated with a heat-resi- Fully open the combustion air into the start-up stant coating, which hardens at a temperature air position and the door ajar (about one cm of about 250°...
1.7 emptying the ash the door. Now open the combustion air com- pletely. If the stove and/or chimney cools down By using the shaker grate, it rotates back and too much, it may be necessary to use the start- forth so the ash falls through the holes and into up air and possibly have the door ajar.
• The temperature difference is too small timal combustion and the highest possible ef- between smoke gasses and outdoor ficiency. Heta wood stoves are constructed so temperature, for ex. poorly insulated chimney that it itself provides an optimal blend of com- •...
1.11 fuel replace one litre of heating oil. All woods have almost the same heating value per kg, which is Your new stove is EN approved for firing with about 5.27 kW/hour for absolute dry wood. wood fuel. You must therefore only burn clean, Wood with a moistness of 18% has a efficiency dry wood in your stove.
1.14 troubleshooting table Fault Cause Troubleshooting Solution Inadequate chimney draft. Lighting problems. When the You can test using a lighter whether Improve the chimney. The chimney only has stove is cold, smoke seeps flame is drawn into the combustion sufficient draft when it is hot. into the room.
1.15 Maintenance 1.16 Cleaning the glass Incorrect firing, for example using wet wood, The surface of the stove is treated with a heat- can result in the viewing window becoming resistant paint. The stove should be cleaned covered in soot. This soot can be easily and with a damp cloth.
1.18 Cleaning after sweeping or before replacing vermiculite stones Note: it may be necessary to clean/vaccum the holes and air ducts behind the rear stone. Order of removing Fire bricks. Replace in reverse order. Starting with Fig. 8.
* Scan-Line 8 - With soapstone: 134 kg. * Scan-Line 8 - With soapstone top and casted sides: 131 kg. The nominal output is the output to which the stove has been tested. Testing is conducted with the combustion air around 50% open.
Page 15
Parts - inside fire chamber Pos. No. Name Qty. 1 0023-0198 Upper baffle 900 Kg / M3 2 0023-0199 Baffle 3 0023-0200 Back stone top 4 0023-0201 Back stone bottom 5 0023-0202 Right side stone back 6 0023-0203 Left side stone back 7 0023-0204 Right side stone front, 8 0023-0205 Left side stone front 9 0030-0023 Casted bottom...
Parts - internal parts Pos. No. Name Qty. Pos. No. Name Qty. 1 0008-0008 Set screw M 4 x 8 14 0008-9067 Tension spring 1x8x60 2 0008-0017 Countersunk screw M4x10 BN 20 5 15 0015-2035 Magnet 3 0008-0041 M6 X 8 allen 16 0015-3003 Adjustment screw M10 x 40 4 0008-0211 M6x16 BN 54 17 0016-0140 Spacers magnet...
Page 17
Parts - self-closing system Pos. No. Name Qty. 1 0008-0903 Hinge pin M6x28 2 0008-1114 M 6 x 20 3 0008-1402 Nut M6 4 0008-9066 Quick lock Ø6 5 0008-9095 Spring 1,4xØ10x68,9 6 0016-0087 Brass bearing for self-closing 7 0016-0128 Extension to the gas cylinder 8 0025-0151 Gas cylinder 9 1012-0096 Spacer for pivot 10 1513-0129 Swivel...
installation instructions Contents Installation instructions ..............19 Distance requirements ..............19 Floor ....................19 Chimney connection ................. 19 Combustion air and ventilation ............20 Stovedrawings/measurments ............20 Clearances for installation ..............21 Changing to a back flue outlet - stoves with casted and/or stone cladding ........22 Changing to a back flue outlet - stoves with steel cladding .....
In front of the fireplace insert, the substrate must be sealed with fireproof material and / or must consist of non-combustible material, for beading. Heta A/S stresses that it is of utmost ex. Steel/glass plate, stone or tile floor. The size...
The Scan-Line 8 has a nominal output of less than 5kW and does not need additional ventila- tion in older properties where it will be ventilated Combustion air and ventilation by natural leakage.
Scan-Line 8 - With soapstone Scan-Line 8 - With soapstone top - With casted sides and casted sides 2.6 Clearances for installation en 13 240 Not combustible Furnitures Combustible material The dimensions are the minimum dimensions, unless otherwise stated.
Secretary of State in accor- dance with changes made to sections 20 and The Scan-Line 8 with and without side windows 21 of the Clean Air Act 1993 by section 15 of have all been recommended as suitable for use the Deregulation Act 2015.