Heta SCAN-LINE 8 Operating And Installation Instructions

Heta SCAN-LINE 8 Operating And Installation Instructions

Hide thumbs Also See for SCAN-LINE 8:

Advertisement

Quick Links

OPERATING AND INSTALLATION
INSTRUCTIONS
SCAN-LINE 8 / SCAN-LINE 8 SCA
Scan-line 8 SCA is exempt for use in smoke control areas when burning dry wood
ECODESIGN READY
www.heta.dk
EN
DANISH DESIGN . DANISH QUALITY . DANISH PRODUCTION
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCAN-LINE 8 and is the answer not in the manual?

Questions and answers

Summary of Contents for Heta SCAN-LINE 8

  • Page 1 OPERATING AND INSTALLATION INSTRUCTIONS SCAN-LINE 8 / SCAN-LINE 8 SCA Scan-line 8 SCA is exempt for use in smoke control areas when burning dry wood ECODESIGN READY www.heta.dk DANISH DESIGN . DANISH QUALITY . DANISH PRODUCTION...
  • Page 2: Declaration Of Performance

    Signed on behalf the manufacturer of 22.02.2017 ____________________________________________________________________________________________________________________ In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid. Heta A/S, Jupitervej 22, DK-7620 Lemvig, Tlf. +45 9663 0600, www.heta.dk Page 1 of 1...
  • Page 3: Table Of Contents

    Scan-Line 8 series have been approved according to the EN 13240, NS 3058/3059 and 15a B-VG and the Scan-Line 8 SCA series are modified so that they are also re- commended as exempt for use within smoke control areas (SCA) throughout the UK (see clean air act Appendix A).
  • Page 4: Before Installation

    It is important that upon receipt check your Heta product completely and report any damage or defects to your dealer. The packaging must be disposed of as follows: Wood is untreated and able to burn in the stove.
  • Page 5 With your new wood stove you should find the following: Q.C. check Operating / Instruction manual Data plate Heta glove 8056-0000-EN DOP-Scan-Line 8 2240-2016 Heta A/S Jupitervej 22 . DK-7620 Lemvig . Denmark Production year: 2016 DS/EN 13240/AEA, NS 3058/3059, Aus §15A Product description: Serial No:...
  • Page 6: Operating Instructions

    The stoves combustion air is controlled by the some firelighters onto the grate with some kind- wheel under the stove door. Scan-Line 8 SCA sto- ling or small pieces of wood to reestablish the ves are designed and tested to burn extremely...
  • Page 7: Refueling

    series of air holes and within the outer vent in fire once again. Leave the air control fully open each side. Fig. 6 and allow the fire to build before refueling with larger pieces of wood. Then adjust the air con- When refueling be careful to place trol for optimum combustion.
  • Page 8: Reduced Burning

    Causing the sealing ficiency. Heta wood stoves are constructed so of the door to tear off when opening the door that it itself provides an optimal blend of com- the next day.
  • Page 9: Fuel

    vantageous wind direction, combined with the pieces of firewood should be of an appropriate position of the chimney can cause negative draft length (approx. 19-25 cm) so that they can lie (it blows through the chimney), causing smoke flat on the bed of embers. escape from the stove.
  • Page 10: Chimney Fire

    damper in the flue gas pipe to regulate the draft. supply completely, to help slow/smother the fire. When cleaning the chimney, soot and other Call the fire department. The stove and chiminey deposits may come to fall on the baffle plate, must be inspected before use again.
  • Page 11: Troubleshooting

    1.18 Troubleshooting table - applies to all stove types Fault Cause Troubleshooting Solution Inadequate chimney draft. Lighting problems. When the You can test using a lighter Improve the chimney. The chimney only has stove is cold, smoke seeps whether flame is drawn into sufficient draft when it is hot.
  • Page 12: Cleaning/Replacing Bicks Scan-Line 8

    1.19 Scan-Line 8. Cleaning after sweeping or before replacing vermiculite stones Note: it may be necessary to clean/vaccum the holes and air ducts behind the rear stone. Order of removing Fire bricks. Replace in reverse order. Starting with Fig. 8.
  • Page 13: Cleaning/Replacing Bicks Scan-Line 8 Side Windows

    1.20 Scan-Line 8 Side windows. Cleaning after sweeping or before replacing vermiculite stones Note: it may be necessary to clean/vaccum the holes and air ducts behind the rear stone. Order of removing Fire bricks.
  • Page 14: Stove Data Table En 13240

    126 kg. * Scan-Line 8 - With soapstone: 134 kg. * Scan-Line 8 - With soapstone top and casted sides: 131 kg. * Scan-Line 8 - With Side windows: 106 kg. The nominal output is the output to which the stove has been tested.
  • Page 15: Parts

    1.23 Parts - Doors 19 8 Pos. No. Name Qty. Pos. No. Name Qty. 1 0008-0021 Flanged M5x10 BN 11252 17 1013-0907 Bracket handle 2 0008-0036 Cylinder screw M4x6 BN 1206 18 1013-0908 Bracket 2 handles 3 0008-0045 Countersunk screw M5 X10 BN20 2 19 1013-0932 Door gasket mounting rails 4 0008-0054 Clanged M6x10 BN 11252...
  • Page 16 Parts - Scan-Line 8 -Inside fire chamber Pos. No. Name Qty. 1 0023-0198 Upper baffle 900 Kg / M3 2 0023-0199 Baffle 3 0023-0200 Back stone top 4 0023-0201 Back stone bottom 5 0023-0202 Right side stone back 6 0023-0203...
  • Page 17 Parts - Scan-Line 8 Side windows - Inside fire chamber Pos. No. Name Qty. 0030-0023 Casted bottom 0030-0201 Casted grate 1519-0019 Log retainer 0023-0199 Baffle 0023-0202 Right side stone back 0023-0200 Back stone top 0023-0198 Upper baffle 0023-0201 Back stone bottom...
  • Page 18 Parts - Internal parts Pos. No. Name Qty. Pos. No. Name Qty. 1 0008-0008 Set screw M 4 x 8 18 1013-0904 Bracket for riddling 2 0008-0017 Countersunk screw M4x10 BN 20 5 19 1013-0921 Door hold 3 0008-0041 M6 X 8 allen 20 1020-0123 Aluminum rail 4 0008-0211 M6x16 BN 54 21 1021-0080 Shaker pin...
  • Page 19 Parts - Self-closing system Pos. No. Name Qty. 1 0008-0903 Hinge pin M6x28 2 0008-1114 M 6 x 20 3 0008-1402 Nut M6 4 0008-9066 Quick lock Ø6 5 0008-9095 Spring 1,4xØ10x68,9 6 0016-0087 Brass bearing for self-closing 7 0016-0128 Extension to the gas cylinder 8 0025-0151 Gas cylinder 9 1012-0096 Spacer for pivot 10 1513-0129 Swivel...
  • Page 20: Installation Instructions

    Installation Instructions Contents Installation instructions ..............21 Distance requirements ..............21 Floor ....................21 Chimney connection ................. 21 Combustion air and ventilation ............22 Stovedrawings/measurments ............22 Clearances for installation ..............23 Changing to a back flue outlet - stoves with casted and/or stone cladding ........24 Changing to a back flue outlet - stoves with steel cladding .....
  • Page 21: Installation Instructions

    / or beading. Heta A/S stresses that it is of utmost In front of the fireplace insert, the substrate importance that this is done correctly with very must consist of non-combustible material, for tight joints.
  • Page 22: Combustion Air And Ventilation

    (excessive weight may damage stalled to an outside air supply. the stove). The Scan-Line 8 has a nominal output of less than 5kW and does not need additional ventila- tion in older properties where it will be ventilated Combustion air and Ventilation by natural leakage.
  • Page 23: Clearances For Installation

    Scan-Line 8 - With soapstone Scan-Line 8 - With soapstone top - With casted sides and casted sides 2.6 Clearances for installation EN 13 240 Not combustible The dimensions are Furnitures the minimum dimen- Combustible material sions, unless other- wise stated.
  • Page 24: Changing To A Back Flue Outlet

    2.7 Changing to a back outlet stoves with casted and/or stone cladding...
  • Page 25: Changing To A Back Flue Outlet - Stoves With Steel Cladding

    2.8 Changing to a back outlet - stoves with steel cladding...
  • Page 26 Secretary of State in accor- dance with changes made to sections 20 and The Scan-Line 8 with and without side windows 21 of the Clean Air Act 1993 by section 15 of have all been recommended as suitable for use the Deregulation Act 2015.

This manual is also suitable for:

Scan-line 8 sca

Table of Contents