8. Programming
icon
6.2
Commands
Info
Menus are displayed in a defined and incremental order.
If none of the buttons are pushed for 5 minutes in the Programming mode, or if there is
a power failure, the controller returns to Service mode without saving.
Mandatory
In order to store the new settings in the programming mode, it is necessary to go
through all the parameters !
1. Press
to pass to the next step.
2. Use
and
6.3
Setting the time of the day (TD)
Set the time in the system.
1. Press and hold
service icon and the parameter display reads TD.
2. Set the time with
3. Press
to validate the selection and return to the service mode, or wait
for 10 seconds.
6.4
Basic programming
6.4.1
Basic programming mode chart
Parameter
DO
Days override
RT
Regeneration
time
H
Feedwater
hardness
RC
Fixed reserve
capacity
SF
Safety factor
CD
Current day
46 / 108
• Appears in programming modes.
to adjust the values.
or
until the programming icon replaces the
or
.
Options
0 to 99
00:00:00 to
23:59:59
1 to 1990
°TH, ppm or
0 to 50
0 to 50
1 to 7
Day of the week
Definition
Day
-
Hour
Regeneration time will not appear
unless regeneration day override is
on.
Only displayed for volumetric
grains
regenerations.
%
Only displayed for volumetric
regenerations and if set in reserve
selection.
%
Only available if set in reserve
selection.
-
Note