Volume Since Last Regeneration (Vu); Reserve Capacity (Rc); Software Version (Sv); Resetting The Controller - Pentair FLECK 9100 SXT Installer Manual

Hide thumbs Also See for FLECK 9100 SXT:
Table of Contents

Advertisement

6.6.5

Volume since last regeneration (VU)

Info
Shows the volume used since the last regeneration (L).
1. Volume since last regeneration display (L or Gal depending on display
format programmed):
6.6.6

Reserve capacity (RC)

Info
Shows the remaining reserve volume until next regeneration (L).
1. Volume until next regeneration display (L or Gal depending on display
format programmed):
6.6.7

Software version (SV)

Info
Shows the version of the software used by the controller.
1. Software version display:
6.7

Resetting the controller

Mandatory
Once you have completed this operation, check all programming steps !
Info
There are two options to reset: partial and hard reset.
Partial reset will set all the parameters to default values, except volume remaining in
volumetric systems and days since last regeneration in time clock systems.
Hard reset will set all the parameters to default values.
6.7.1

Soft reset (SR)

1. Press and hold
until SR is displayed.
2. Reprogram all parameters in Master programming mode.
Ref. MKT-IM-004 / E - 06.10.2020
and
for 25 seconds while in normal service mode
Installer manual Fleck 9100 SXT - Programming