Installer manual Fleck 9100 SXT - Maintenance
9.4.3

Controller replacement

1. Loosen the wheels (1) and open the valve cover (2).
2. Push the controller (3).
3. Press the controller clips (5) and open the controller cover (4).
4. Disconnect the old controller (7) and remove it opening the card clips (6).
5. Connect the new controller, see Electrical connections [
Page 39]
6. Reverse above procedure steps to rebuild..
Ref. MKT-IM-004 / E - 06.10.2020
71 / 108