Do A Check On The Appliance; Maintenance Procedures; Remove The Glass Panes - Bellfires Smart Bell Panorama 45/59 MF Installation And Maintenance Manual

Table of Contents

Advertisement

5 5 .1.2

Do a check on the appliance

1.
2.
3.
4.
5.
6.
5.2

Maintenance procedures

5.2.1

Remove the glass panes

1.
2.
3.
4.
Smart Bell Panorama 45/59
Do a check for leaks on the gas pipes and the gas pipe connections. Refer to
Make sure that the pilot light operates correctly. The pilot light must not show any
anomalies.
Make sure that the main burner operates correctly. The fire must not show any
anomalies.
Do a check of the gas supply pressure and the burner pressure.
a)
Use the inlet pressure tap and outlet pressure tap on the gas regulator block to
measure the supply pressure and the burner pressure.
b)
Measure the pressure when the appliance is off and when the appliance burns
on maximum. Refer to
Make sure that the ambient lighting operates correctly. Refer to
Do a check on the concentric flue system and the outlet construction. Make sure that
all the connections of the concentric flue system are secure.
Caution:
Use protective gloves.
Turn off the gas supply to the appliance before removing the glass panes.
Remove the side panels and front panel.
Unlock the fastening levers on the top left and right of the glass panes.
Lift the front glass pane a little, and remove it in a slanted manner.
7
for the required supply pressure and burner pressure.
Maintenance
4.2.4
.
4.3.1
.
29

Advertisement

Table of Contents
loading

Table of Contents