Gas fires with closed combustion system original bell-series - retro bell-series horizon bell medium / small-series - corner bell small l/r vertical bell-series - view bell-series (90 pages)
Gas fi res with closed combustion system (88 pages)
Summary of Contents for Bellfires Smart Bell Panorama 45/59 MF
Page 1
I I nstallation and maintenance manual Smart Bell Panorama 45/59 MF Serial number: Production date:...
Page 2
Barbas Bellfires BV. This document could contain technical inaccuracies or typographical errors. Barbas Bellfires BV reserves the right to revise this document from time to time in the contents thereof.
Contents C C ontents About this document................5 How to work with this document....................5 Warnings and cautions used in this document................5 Related documentation........................ 5 Description....................6 Intended use..........................6 Installation options........................6 Overview of a typical installation....................6 Overview of the appliance......................7 Overview of the burner bed and the pilot light................
Page 4
5.2.4 Replace the ambient light bulb when broken..............32 Troubleshooting..................33 Technical specification................34 Smart Bell Panorama 45/59 MF (MagniFire) - GB, IE, ES, IT........... 34 Diagram electricity and gas......................36 Dimensions Smart Bell Panorama 45/59................... 37 Dimensions of the restriction plate.....................38 Warranty Terms..................
• Maintenance This document refers to the Smart Bell Panorama 45/59 MF as 'the appliance'. This document is an essential part of your appliance. Read it carefully before you do work on the appliance. Keep it in a safe place.
Description Description Intended use The appliance is intended for use in a completely sealed or mechanically ventilated house without extra ventilation and/or fume extraction to heat the room wherein it is installed. Do not use it for other purposes. The appliance may only be used at a location that meets the requirements for the installation of the appliance.
Description I I tem Description Inlet grate Provides the fireplace with air Outlet grate The heated air in the fireplace is extracted by the outlet grates into the room Concentric flue system (wall outlet variant) The concentric flue system provides combus- tion air to the appliance and extracts the flue gases from the appliance Overview of the appliance...
Description I I tem Description Convection casing Collects the heated convection air. The con- vection air has a natural upward flow and is extracted by the upper front side openings of the appliance DO NOT COVER openings Protects the appliance against an overpres- sure Overview of the burner bed and the pilot light Item...
Description 2 2 .6 Overview of the ceramic log set No. Ember grate No. Ember grate with pilot opening No. 'Fire glass' Dark Amber No. Embers Smart Bell Panorama 45/59...
Page 10
Description N N o. Log No. Charcoal No. Wood chip No. Wood chip Smart Bell Panorama 45/59...
Description N N o. Wood chip No. Wood chip Overview of the control elements 2.7.1 Overview of the rear of the gas regulator block Item Description Inlet pressure tap Point to measure the gas supply pressure Outlet pressure tap Point to measure the front burner pressure Gas supply connection The connection for the gas supply pipe Gas connection for the front burner...
Description 2 2 .7.2 Overview of the front of the gas regulator block Description Pilot gas adjustment screw Sets the pilot light gas pressure. The adjust- ment screw is factory set and sealed. Adjustment screw maximum burner pressure Sets the maximum gas pressure for the burn- er.
Description 2 2 .7.3 Overview of the connections on the gas regulator block Item Description Pilot light pipe Supplies gas to the pilot light burner Thermocouple Detects if the pilot light is on Connector (nut-olive) Ø 4mm Connects the pilot light gas pipe to the gas regulator block Thermocouple interrupter Interrupts the signal of the thermocouple, and...
Connection for a wifi-box (SI) Optionally, a wifi-box can be connected to the receiver to control the appliance with a smart- phone or tablet with the Bellfires app Connection for the fan/light module (MOD- To control the light function ULE)
Description 2 2 .7.5 Overview of the fan/light module Item Description Connection for the ambient lights Powers the ambient light bulbs Connection for a convection fan Not applicable for this appliance connection for the power supply Connection for the 230 VAC power cable with an earthed plug.
Safety Safety Safety devices on the appliance Name Description Thermo-electric pilot light shut off Prevents unforseen discharge of gas from the main burner. Overpressure door (= glass front) and If an overpressure occurs in the appliance, the glass overpressure hatch front door and the hatch opens for a short duration.
Safety C C aution: • Only use the items that are supplied or described in the preparation manual and other related documentation. • Do not use masking tape on the appliance. Masking tape can damage the finish of the appliance. •...
Installation Installation Installation prerequisites Make sure that the location agrees with the requirements. Refer to the preparation manual. Make sure that the details of the rating plate of the appliance agree with the gas type and gas pressure of the gas supply. Installation procedure Note: The appliance is factory set to the correct nominal heat input.
Installation 4 4 .2.2 Horizontally align the appliance • Adjust the adjustable feet. Use an hexagonal key of size 4. Make sure that distance x is at least 1 cm. Make sure that the appliance is installed horizontally. 4.2.3 Make the gas connection Caution: •...
Installation 4 4 .2.6 Connect the concentric flue system Connect the concentric flue system to the appliance. Use the materials that are specified in the preparation manual. Do not use any other materials. Make sure that all mechanical connections of the concentric flue system are correctly connected.
Installation Baffle plate has been removed. (The use of a restriction plate, without a baffle plate, is not allowed.) 4 4 .2.9 Build the fireplace Safety conditions Caution: • Remove the side panels and the front panel of the frame to prevent 5.2.1 damage of the frame during work.
Installation 4 4 .3 Prepare the appliance for use • Do all the procedures in this section. Optional procedures are indicated with (optional). 4.3.1 Do a check on the operation of the lighting • Make sure that the operation of the ambient lights function well. To operate the lights with the remote control, refer to the user manual 4.3.2 Put the ceramic log set on the burner bed...
Page 23
Installation P P reparation Make sure that all items of the log set are there. See Put the ceramic ember grates on the lower and upper main burner, as shown below. Refer to for the numbers of the items. Smart Bell Panorama 45/59...
Page 24
Installation Spread the fire glass -dark amber- evenly on the metal grate in front of the burner bed. N N ote: Set the light intensity of the ambient lighting to maximum on the remote control. Refer to the user manual. Make sure that the light intensity is the same everywhere.
Page 25
Installation Spread the embers evenly behind and beside the burner bed. C C aution: Do not apply embers on the openings of the ember grates. Embers in the openings of the ember grates can cause a blockage of the openings. Put the charcoal pieces and chips of wood at the designated places around the burner bed.
Page 26
Installation Put the logs on the burner bed. Refer to for the numbers of the items. 5.2.2 Install the glass. Refer to 2 2 6 Smart Bell Panorama 45/59...
Installation 4 4 .3.3 Do a final check on the fireplace Safety conditions Caution: Wait 4 weeks after the installation before you use the fireplace. The cement needs to harden. A final check on the fireplace can be done directly after the installation.
• Do all procedures in this section every year. Caution: • Use only original parts. Individual parts for replacement or accessories are available from your BELLFIRES-dealer. • Introduced modifications to the appliance are not permitted. 5.1.1 Clean the appliance Safety conditions Caution: •...
Maintenance 5 5 .1.2 Do a check on the appliance 4.2.4 Do a check for leaks on the gas pipes and the gas pipe connections. Refer to Make sure that the pilot light operates correctly. The pilot light must not show any anomalies.
Maintenance Loosen the screws left and right of the top side strips. Do not remove the screws and strips. Remove the glass panes on the sides with the same procedure as the front glass. 5 5 .2.2 Install the glass panes Caution: Use protective gloves.
Page 31
Maintenance Tighten the screws left and right of the top side strips. Install the front glass pane, by lifting the glass a little in a slanted manner and place it in the strips (top and bottom) . Lock the fastening levers on the top left and right of the glass panes. Install the front panel and side panels.
Maintenance C C aution: • Make sure whether the front glass pane is placed exactly in the middle. • Make sure that there are no gaps between the glass panes. Otherwise, there is risk of flue gas leakage. 5.2.3 Clean the glass Clean the glass with a soft cloth, a sponge or paper.
Troubleshooting Troubleshooting Problem possible cause solution The main fire stops to burn The concentric flue system is Install the concentric flue sys- not installed according to the tem correctly. Refer to the specified instructions. preparation manual. An incorrect flue gas restriction Install the correct gas restric- 4.2.7 plate is fitted.
Technical specification Technical specification Smart Bell Panorama 45/59 MF (MagniFire) - GB, IE, ES, IT Natural gas Butane/ Propane Name Bellfires Bellfires Model Smart Bell Panorama 45/59 MF Smart Bell Panorama 45/59 MF Country GB, IE, ES, IT GB, IE, ES, IT...
Page 35
Technical specification N N atural gas Butane/ Propane Pilot light burner SIT 0.145.019 SIT 0.145.019 Pilot light burner injector no 36 (SIT 0.977.091) no 23 (SIT 0.977.150) Gas connection 3/8” G / Ø12 mm 3/8” G / Ø12 mm Concentric flue system connec- Ø100 mm - Ø150 mm Ø100 mm - Ø150 mm tion...
Technical specification 7 7 .2 Diagram electricity and gas Item Main burners Gas regulator block Gas valve of the rear burner Receiver Fan/Light module Ambient lighting Gas pipe rear burner Gas pipe front burner Gas supply connection Pilot light burner Pilot light pipe Piezo cable Thermocouple...
Technical specification 7 7 .4 Dimensions of the restriction plate Width of the delivered flue restriction plates in mm Concentric flue connection Ø100 - Ø150 Roof-mounted outlet Smart Bell Panorama 45/59...
Complaints will only be accepted if they are reported to the Bellfires dealer, together with the serial number of the Bellfires appliance which is stated on the front of the user manual. In addition, the original receipt (invoice, receipt, cash receipt) showing the date of purchase must also be submitted.
Page 40
Article 5: Warranty period This warranty will only be granted during the warranty period. The body of the Bellfires appliance is guaranteed for a period of 10 years against construction and/or material faults, starting from the moment of purchase. For other parts of the Bellfires appliance, a similar warranty applies from the moment of purchase for a period of two years.