Preparation manual Smart Bell 80/60 MF Serial number: Production date:...
Page 2
Barbas Bellfires BV. This document could contain technical inaccuracies or typographical errors. Barbas Bellfires BV reserves the right to revise this document from time to time in the contents thereof.
Dimensions of the restriction plate.....................23 Available components for the concentric flue system......24 Appliance part list........................24 Bellfires - Muelink & Grol system Ø100 - Ø150................. 25 Poujoulat - DUOGAS system Ø100 - Ø150................29 Ontop - Metaloterm US system Ø100 - Ø150................32 Jeremias/STB - H-Twin system Ø100 - Ø150................36...
About this document About this document This document shows the necessary information to do these tasks on the Smart Bell 80/60 MF: • Preparation for installation This document refers to the Smart Bell 80/60 MF as 'the appliance'. This document is an essential part of your appliance.
Overview of the concentric flue system Overview of the concentric flue system The concentric flue system provides the appliance with combustion air and removes the flue gases from the appliance. The concentric flue system is made of these items: Item Description Concentric flue The concentric flue is a pipe with an inner pipe.
Only use items in the installation that are specified in this manual and the related documents. • Only use the following brands for the installation of the concentric flue system: Manufacturer system Bellfires Muelink & Grol system Poujoulat DUOGAS system Ontop Metaloterm US system Jeremias/STB (STB = Schoorsteen...
Requirements Requirements Requirements on the location • Never use combustible building materials for the fireplace. • Do not install the appliance against a flammable rear wall. • Install a nonflammable insulation plate of at least 12 mm between the appliance and the rear wall.
Requirements Minimum distance between the items Location of any of the items(*) and the roof outlet At the same roof as the outlet At a different roof as the outlet At a lower positioned wall than the outlet At a higher sloping surface than the outlet (*) Items: •...
Requirements • A ventilation opening that services an occupied room, a toilet or a bathroom. • A combustion air supply, if the supply flows through an occupied room. • A window that can be opened that services an occupied room, a toilet or a bathroom. (**) If an obstruction protrudes at least 0.5 meter between the item and the outlet and the obstruction has a lenght of at least the recommended minimum distance, ignore the recommended minimum distance.
Requirements 4.4.1 Possibilities for a concentric flue system with a roof outlet Rigid concentric flue systems 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) Ø100-Ø150 mm 2.0 - 4.0 m 30 mm 4.0 - 12.0 m 40 mm Smart Bell 80-60...
Page 11
Requirements 14,15 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) (min. - max.) (min. - max.) Ø100-Ø150 mm 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m Caution: Make sure that Y is at least 2 times larger than X.
Page 12
Requirements Flexible concentric flue systems 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) Ø100-Ø150 mm 2.0 - 4.0 m 30 mm 4.0 - 12.0 m 40 mm Roof outlet using an flexible Ø100 mm liner in an existing lined chimney. Smart Bell 80-60...
Page 13
Requirements ≥45° 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) (min. - max.) (min. - max.) Ø100-Ø150 mm 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m Caution: Make sure that Y is at least 2 times larger than X.
Page 14
Requirements 27,28,29 26,29 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) Ø100-Ø150 mm 2.0 - 4.0 m 30 mm 4.0 - 12.0 m 40 mm Roof outlet using an flexible Ø100 mm liner and flexible Ø150 mm liner in an existing unsound lined chimney.
Requirements ≥45° 27,28,29 26,29 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) (min. - max.) (min. - max.) Ø100-Ø150 mm 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m Caution: Make sure that Y is at least 2 times larger than X.
Page 16
Requirements Rigid concentric flue systems 0.16 m 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on (min. - max.) (min. - max.) the appliance is Ø100- Ø150 mm 1.0 - 3.0 m 0 - 3.0 m 3.0 - 5.0 m 0 - 7.0 m Smart Bell 80-60...
Technical specification Dimensions Smart Bell 80/60 with an Insert frame 50 mm and Convection fan Dimensions of the restriction plate Width of the delivered flue restriction plates in mm Concentric flue connection Ø100 - Ø150 Roof-mounted outlet Smart Bell 80-60...
European CE-norm for gas appliances and may therefore be used only with these systems. Table 1: Approved brands Manufacturer system Bellfires Muelink & Grol system Poujoulat DUOGAS system Ontop Metaloterm US system...
Available components for the concentric flue system Bellfires - Muelink & Grol system Ø100 - Ø150 Bellfires Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Twin-wall balanced flue pipe. 302289 ● ● L= 500 mm. Twin-wall balanced flue pipe.
Page 26
Available components for the concentric flue system Bellfires Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Twin-wall balanced flue el- 302298 ● ● bow 45°. Vertical (roof) termination kit, 302295 ● ● ● ● L= 1360 mm.
Page 27
Available components for the concentric flue system Bellfires Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Ceiling plate for transition 302189 Ø100 mm / Ø150 mm rigid - ● ● ● Ø100 mm (flex.). Stainless steel adapter piece (100) from fire to fl...
Page 28
Available components for the concentric flue system Bellfires Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Vertical (roof) termination kit, 302307 L = 610 mm. Suitable for a ● ● ● ● flexible flue system. Concentric T-piece with 302301 ●...
Available components for the concentric flue system Poujoulat - DUOGAS system Ø100 - Ø150 Poujoulat Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Twin-wall balanced flue pipe, L= 250 mm. 37100403 Twin-wall balanced flue pipe. 37100404 ●...
Page 30
Available components for the concentric flue system Poujoulat Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Vertical (roof) termination kit, 37100654 ● ● L= 140 mm . Roof flashing, suitable for a 45150171 brick roof, with a roof pitch of ●...
Page 31
Available components for the concentric flue system Poujoulat Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Ceiling/wall plate with 37100442 spacers and ventilation ● ● grooves. Set of ceiling finishing plates / 37100425 Fire stops, suitable for a roof ●...
Available components for the concentric flue system Ontop - Metaloterm US system Ø100 - Ø150 Ontop Art./ Color (*) Application Fig. ORDER DESCRIPTION antr. rigid flex Adapter for Bellfires applian- USA 10 ces with Ø100-Ø150 mm ● ● concentric connection. Twin-wall balanced flue pipe, US 25 10 ●...
Page 33
Available components for the concentric flue system Ontop Art./ Color (*) Application Fig. ORDER DESCRIPTION antr. rigid flex Twin-wall balanced flue el- USB 15 10 ● ● bow 15°. Vertical (roof) termination kit, USDVC2 10 ● ● L= 375 mm. USSR 10 Storm collar Ø150 mm.
Page 34
Available components for the concentric flue system Ontop Art./ Color (*) Application Fig. ORDER DESCRIPTION antr. rigid flex USAB 10 Cover band, screw-fastening. ● ● USMB 10 Wall strap, adjustable. ● ● USEB 10 Fitting bracket. ● ● Set of ceiling finishing plates / USCP 10 ●...
Page 35
Available components for the concentric flue system Ontop Art./ Color (*) Application Fig. ORDER DESCRIPTION antr. rigid flex Locking band, screw-fasten- USKBS 10 ● ● ing. Concentric pipe with inspec- USI 10 ● ● tion panel, L= 250 mm. Concentric pipe with gauging USEM 10 ●...
Available components for the concentric flue system Jeremias/STB - H-Twin system Ø100 - Ø150 Jeremias Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. ATWINL 13 Twin-wall balanced flue pipe. ● ● 100-150 L= 1000 mm. ATWINL 14 Twin-wall balanced flue pipe.
Page 37
Available components for the concentric flue system Jeremias Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. ATWIN 17 Twin-wall balanced flue el- ● ● 100-150 bow 30°. ATWIN 18 Twin-wall balanced flue el- ● ● 100-150 bow 45°.
Page 38
Available components for the concentric flue system Jeremias Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. ATWIN 92 Roof termination - short with ● ● ● 100-150 pipe, L = 300 mm, Vertical. Roof termination, with pipe, L ATWIN = 495 mm, Vertical, with roof 92pe...
Page 39
Available components for the concentric flue system Jeremias Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Horizontal (wall) termination A681 kit, L= 495 mm (horizontally ● ● 100-150 adjustable), including one set of wall spacer plates. Concentric T-piece with H-TWIN 752 gauging orifice.
Available components for the concentric flue system Jeremias - TWIN-GAS system Ø100 - Ø150 Jeremias Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Bellfires Appliance connec- tion / Adapter Bellfires TWG1634 Ø100/150 mm → Jeremias ● ●...
Page 41
Available components for the concentric flue system Jeremias Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Telescopic twin-wall balanced TWG50 flue pipe, L= min. 330 / max. ● ● 100-150 420 mm Including locking band. Twin-wall balanced flue el- TWG16 bow 15°.
Page 42
Available components for the concentric flue system Jeremias Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Roof termination (vertical) L= TWG272 615 mm. Including locking ● ● 100-150 band. Roof flashing with a roof pitch TW53 150 of 5°...
Page 43
Available components for the concentric flue system Jeremias Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Locking band, screw-fasten- TW45 150 ● ● ing (spare part). Silicone sealing ring for outer ALBI26 150 ● pipe (spare part). ZUWA704 Wall strap.
Page 44
Available components for the concentric flue system Jeremias Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Set of ceiling finishing plates / Fire stops with ventilation DA99VHL ● ● openings for a pitched roof : 0° - 30°. Set of ceiling finishing plates / Fire stops with ventilation DA98VHL...
Page 45
Available components for the concentric flue system Jeremias Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Base plate/Cover-under with TWG05 2x ½” gauging orifice, sealing ● ● 100-150 cap and condensate drain at the bottom. TWG07 Base plate / floor support.
Page 46
Available components for the concentric flue system Smart Bell 80-60...
Page 47
Available components for the concentric flue system Smart Bell 80-60...
Page 48